background image

Propiedad de Vendwatch Telematics - Con

fi

dencial 

VM CONNECT T313 

USER MANUAL  

Version 0.07 

Summary of Contents for VendMine Connect T313

Page 1: ...Propiedad de Vendwatch Telematics Confidencial VM CONNECT T313 USER MANUAL Version 0 07...

Page 2: ...0 02 Installation Feedback APRIL 12 2016 0 03 Added EPay display status JUNE 1 2016 0 04 Swapped the mounting brackets solely to magnets JUNE 3 2016 0 05 Replaced picture of device with magnet captiv...

Page 3: ...es using general guidelines applicable to a universal principle of operation Other documents would detail specific mounting location and cable routing for the various models available in the market fr...

Page 4: ...ner includes the T313 Telemetry Device the telemetry antenna and the accessories kit Clips to mount the enclosure and splice connectors to connect the door switch are found inside the kit amongst othe...

Page 5: ...clips included in the kit provide flexibility of installation the desired location is accomplished by inserting the clips right to left or left to right see picture below allowing the unit to be atta...

Page 6: ...cables connecting the unit to the VM controller Direct EXchange DEX port the Electronic Payment EPay System the Multi Drop Bus MDB serving the legacy payment system the Door Switch and Temperature Se...

Page 7: ...where the T303 Telemetry Device is installed To do this you will need to drill a 5 8 hole using the conical drill bit as shown Once drilling is completed remove the hex nut from the antenna and inser...

Page 8: ...or The VM Controller VMC the intelligence behind the VM functionality provides a DEX interface connector phone jack in some models solder directly on the board and other models as a dongle Find the DE...

Page 9: ...The Electronic Payment EPay unit should be mounted on the VM using as a minimum two of the mounting metal inserts in the back of the EPay unit When necessary an additional perforation of the chassis...

Page 10: ...s together Additional 1 meter extension cables can be purchased if the distance between the T313 and the EPay devices exceeds 1 5 meters Upon powering up the unit the EPay unit will display Reader Cur...

Page 11: ...nnect to the MDB bus The installation would require to find the last device on the MDB bus and connect the T313 Telemetry Device at the end If the last device on the bus does not have a spare connecto...

Page 12: ...GE NO Pair BROWN BLACK VT NO Switch Kit available for sale GREEN YELLOW The VM is equipped with a door switch connected to the VMC typically one of the poles is connected to what s universally referre...

Page 13: ...NO POLE and the COMMON POLE ARE NOT making contact while the NC POLE and the COMMON POLE ARE making contact with each other To facilitate the integration of the VM door switch with the Telemetry devi...

Page 14: ...tester tool to make contact with one of the wired poles If the light of the Continuity Tester Tool turns ON press and release the Door Switch button if the light is still ON no matter what state the D...

Page 15: ...e the switch model and the poles connectivity DOOR SWITCH LIGHT SOUND POLE TYPE SWITCH TYPE Extended or Pressed YES Common Unknown Extended NO NO Normally Open Pressed YES NO Normally Open Extended YE...

Page 16: ...pole of switch 1 Locate the RED Wire in the Door Switch Cable of the T313 Telemetry and splice it with the wire still connected to the switch using one of the UY2 connector 2 Locate the ORANGE Wire i...

Page 17: ...of the switch 1 Locate the BLACK Wire in the Door Switch Cable of the T313 Telemetry and splice it with the wire still connected to the switch using one of the UY2 connector 2 Locate the BROWN Wire i...

Page 18: ...Black and Red wires will be available Cut the NO wire and join the Black one to the Door Switch and the Red one to the VMC NORMALLY OPEN NO WIRING DIAGRAM WITH EXTENSION T31x Coffee Black VMC Red Blac...

Page 19: ...unit the label at the front bottom of the unit houses the Electronic Serial Number ESN The GEAR icon illustrate the location of the configuration switch a special key will be provided to qualified te...

Page 20: ...emetry module Radio Training Green On 50 Radio is searching for available networks Radio Connected Green On 87 Radio is connected to selected network THE BEHAVIOUR OF THE STATUS LED STATE ILLUMINATION...

Page 21: ...GSM 850 4 2W PCS 1900 1 1W EDGE 850 MHz E2 0 5W EDGE 1900 MHz Class E2 0 4W WCDMA FDD B2 B5 Class 3 0 25 W FREQUENCY STABILITY The GSM system is made in a way tha the RF transmission is not continuous...

Page 22: ...Propiedad de Vendwatch Telematics Confidencial TELIT UL865 NAD MODULE The Vendwatch VIU contains the Telit UL865 NAD cellular module FCC ID R17UL865NA FCC DECLARATION OF CONFORMITY...

Page 23: ...1900B 2 15 MAIN TECHNICAL SPECIFICATION FRECUENCY 824 960 1710 1990MHz VSWR 1 5 GAIN 2 15dBi POLARIZATION TYPE Vertical RATED POWER 50w IMPEDANCE 50 CONNECTOR TYPE SMA DIMENSIONS 28 5X225 mm CABLE TY...

Page 24: ...ECUENCY RANGE MHz 698 960 1710 2700 VSWR 2 5 1 PEAK REALISED GAIN ISOTROPIC 700MHz 3dBi 800 MHz 3dBi 900 MHz 4dBi 1800 MHz 4dBi 1900 MHz 5dBi 2100 MHz 5dBi 2400 MHz 5dBi 2600 MHz 5dBi VSWR 2 5 1 POLAR...

Reviews: