T3.5 AUTO / T5 AUTO
230V
˜
50Hz
S.A.S. au capital de 5 000 000
!
- Z.I. Les Giranaux - BP71 - F70103 Arc-Les-Gray CEDEX - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
5052442E
EN- ORGINAL INSTRUCTIONS
-20°C / +60°C
These instructions apply to all T3.5 AUTO / T5 AUTO drive, the different versions of which are available in the current catalogue.
Field of application:
T3.5 AUTO / T5 AUTO drive are designed to drive all types of roller shutters equipped with stop blocks and rigid links.
The installer, who must be a motorisation and home automation professional, must ensure that the drive product is installed in accordance with
the standards in force in the country in which it is installed such as EN 13659 relating to roller shutters.
Liability:
Before installing and using the drive, please read operating and installation guide carefully.
In addition to following the
instructions given in this guide, the instructions detailed in the attached
Safety instructions
document must also be observed. The drive must
be installed by a drive and home automation professional, according to instructions from SIMU and the regulations applicable in the country in
which it is commissioned. It is prohibited to use the drive outside the fields of application described above. Such use, and any failure to comply
with the instructions given in this guide and in the attached
Safety instructions
document, absolves SIMU of any liability and invalidates the
warranty. The installer must inform its customers of the operating and maintenance conditions for the drive and must provide them with the
instructions for use and maintenance, and the attached
Safety instructions
document, after installing the. Any After-Sales Service operation
on the drive must be performed by a drive and home automation professional. If in doubt when installing the drive, or to obtain additional
information, contact a SIMU adviser or go to the website
www.simu.com
Instructions which must be followed by the drive and home automation professional installing the
drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
T3.5 AUTO:
The cable for the T3.5 AUTO cannot be removed. If it is damaged, return the drive to the
After-Sales department.
T5 AUTO:
The cable for the T5 AUTO can be removed. If it is damaged, replace by the same. The cable
may only be connected to the motor by qualified personnel. The connector is to be assembled without
damaging the contacts. The continuity of the earth connection must be ensured.
Recommendations:
The motor torque must be selected according to the shutter’s characteristics. Do
not oversize the operator. To receive information regarding the compatibility of the motor and the roller shutter or/and accessories,
contact the roller shutter manufacturer or SIMU.
Drilling of the tube:
Installation
1
i
MANDATORY
V.A.R
V.A.S
EASYLINK
OCOTEASY
Ø4 x 10 / 120°
STEEL
2
3
1
5
4
Ø4,8 x 10
Ø5 x 10
STEEL
5.3 Nm max
3
2
1
2
2
1
1
35 N.m max.
Mounting T3.5 AUTO:
1/2
Mounting T5 AUTO:
A
(mm)
ØB
(mm)
L1
(mm)
L2
(mm)
A
4 x ØB / 90°
37
min.
4.16
448
4.2
471
485
483
506
520
9.16 - 13.10
T3.5 AUTO
230V
˜
50Hz
L2
L1
29
Ø38,2
IP 44
A
4 x ØB / 90°
47
min.
6.17 - 10.17
15.17
20.17 - 25.17 - 35.17
L1
L2
4
22,8
55
48*
* 35 Nm max.
T5 AUTO
230V
˜
50Hz
A
(mm)
ØB
(mm)
L1
(mm)
L2
(mm)
485
5
498
521
505
518
541
659
672
695
IP 44
EN