background image

1/5

-  Selection charts and limits of use mentioned in this document are given for information and may vary according to each installation characteristics 

(more particularly : type of slats, frictions, conditions of installation, variations in power supply voltage, torque variations due to each grilles and 

metal curtains kinematics and to its springs strength). That can not commit the salesman or manufacturer’s responsibility at all.

-  All technical data below are given to nominal torque of the motor and with à correct balance by springs (= disengaging the motor should not cause 

movements of the curtain - the curtain must be manoeuvrable manually by one person).

EN-

  

CENTRIS MOTOR

INSTALLATION MANUAL

Public limited company with capital of €5,000,000 - Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - FRANCE - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - EEC VAT No. FR 87 425 650 090

5062718I

EN - TRANSLATION OF THE 

ORIGINAL MANUAL

Read this manual carefully before using the 

machine.

This manual applies to all CENTRIS motors (S, M, L, XL, XXL) powered with 230V/50Hz, 240V/50Hz and CENTRIS motors (100, 200) powered 

with 120V/60Hz (torque/speed versions detailed in chapter 1).

Mandatory instructions to be followed by the motor and building automation professional installing the motor.

CENTRIS motors are intended to activate vertical winding doors and windows equipped with compensation systems, such as curtains or grills 

for commercial or industrial premises, whose winding systems are protected against falling or against uncontrolled imbalance movements, if a 

single suspension system or balancing system component fails. The fitter, a motorization and building automation professional, must insure, after 

installation, that the installation is conform with local standards and particularly with EN 13241-1.

Read this manual carefully before installing and using the CENTRIS motor. In addition to the instructions described in this manual, you must also 

follow the instructions detailed in the attached document 

"ICC Safety Instructions". 

The motor must be installed by a motor and building automation professional, in accordance with the SIMU instructions and the regulations applicable 

in the country of use. 

All use of CENTRIS motors outside the scope of application described above is prohibited. This frees SIMU from all liability and warranty obliga-

tions, as does failure to respect the instructions in this manual and in the attached document 

"ICC Safety Instructions"

.

The installer must inform their customers of the conditions for using and maintaining the CENTRIS motor and must provide them with the use and 

maintenance instructions, as well as the attached document 

"ICC Safety Instructions"

, after installing the CENTRIS motor.

All operations on the CENTRIS motor, including After Sales Service, require the intervention of a motor and building automation professional. If 

you have any doubts while installing the CENTRIS motor or if you require any additional information, get in touch with a SIMU contact or visit the 

website 

www.simu.com.

SCOPE

LIABILITY

SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input 

voltage 230V~50Hz,120V~60Hz, 240V~50Hz and used as intended according to these instructions, is in compliance with the 

essential requirements of the applicable European Directives and in particular of the Machinery Directive 2006/42/EC and EMC 

Directive 2014/30/EU.

The full text of the EU declaration of conformity is available at www.simu.com.  

Emmanuel CARMIER, general director, GRAY, 01/2018.

EN

The CENTRIS motor is designed to be controlled exclusively by the following SIMU products: Key switch with declutching, External declutching box, 

Universal key switch, Unstable key switch, RSA Hz and RSA Hz PRO.

COMPATIBILITY

Summary of Contents for CENTRIS

Page 1: ...ant dans cette notice et dans le document joint Consignes de s curit ICC toute responsabilit et garantie de SIMU L installateur doit informer ses clients des conditions d utilisation et de maintenance...

Page 2: ...VF Blanc longueur 4 m tres d gain d nud et coss 120V 60Hz Style 2464 Blanc longueur 4 m tres d gain d nud et coss C BLE DE D BRAYAGE Longueur 6 m tres CENTRIS S M L XL CENTRIS 100 USA CENTRIS XXL CENT...

Page 3: ...2 220 240 5 mm 6 mm 5 5 13 mm 45 N m 0 MAX 0 4 3 Moteur avec fixation par bride Moteur avec fixation par mors de serrage 3 1 Pr paration du tube pour un moteur avec fixation par bride 3 2 Installatio...

Page 4: ...la couronne est gauche sortie des c bles droite ou inversement Toujours faire une boucle sur le c ble d alimentation pour viter la p n tration d eau dans la motorisation Les c bles traversant une paro...

Page 5: ...Connecteur rapide sans vis L N PE 4 230V 50Hz 120V 60Hz Vert jaune Vert PE Bleu Blanc N Marron Noir L1 Noir Rouge L2 1 2 3 OK 30 N m 3 8 mm 30 N m 3 8 mm b c d i e f g 1 2 5 x 5 x 1 7 1 Identificatio...

Page 6: ...ead this manual carefully before installing and using the CENTRIS motor In addition to the instructions described in this manual you must also follow the instructions detailed in the attached document...

Page 7: ...yle 2464 White length 4 metres stripped and lugged CLUTCH CABLE Length 6 metres EN i CENTRIS S M L XL CENTRIS 100 USA CENTRIS XXL CENTRIS 200 USA Description Torque N m Power supply Crown mm Power W I...

Page 8: ...3 mm 45 N m 0 MAX 0 4 3 Motor with clamp fixing Motor with fixing by clamping jaws 3 1 Tube preparation for motors with clamp fixing 3 2 Installation of motors with clamp fixing steps 1 to 7 Fitting o...

Page 9: ...cable in the motor alignment Always make a loop with the power cable to avoid any water entering the motor Cables passing through a metal wall must be protected and insulated by a sleeve or duct Tie u...

Page 10: ...the switch g Up end limit 1 Put electrically the shutter to the UP wished position noise of the blades i 2 Move the shutter down up to the floor 3 Remove the memory ring of the left side b 4 Turn the...

Page 11: ...ocumento adjunto Instrucciones de seguridad ICC El motor debe ser instalado por un profesional de la motorizaci n y automatizaci n de edificios siguiendo las instrucciones de SIMU y de acuerdo con la...

Page 12: ...to pelado y con terminal 120V 60Hz Style 2464 Blanco longitud 4 metros sin recubrimiento pelado y con terminal CABLE DE DESEMBRAGUE Longitud 6 metros ES i CENTRIS S M L XL CENTRIS 100 USA CENTRIS XXL...

Page 13: ...240 5 mm 6 mm 5 5 13 mm 45 N m 0 MAX 0 4 3 Motor con fijaci n por brida Motor con fijaci n por abrazaderas eje 76 mm 3 1 Preparaci n del tubo para un motor por fijaci n por brida 3 2 Instalaci n de u...

Page 14: ...los cables a la derecha o inversamente D siempre una vuelta al cable de alimentaci n para evitar la penetraci n de agua en el motor Los cables que atraviesan una pared met lica deben ir protegidos y a...

Page 15: ...la direcci n hasta activar el micro interruptor g Fin de carrera punto alto 1 mover el ctricamente la persiana hasta la posici n alta deseada 2 mover la persiana hacia abajo hasta el suelo 3 Extraer...