Attaching the shutter
(all Centris range)
6
End limits adjustment
(all Centris range)
7
230V - 50Hz
120V - 60Hz
Green / yellow
Green
PE
Blue
White
N
Brown
Black
L1
Black
Red
L2
b
c
d
i
e
f
g
=
=
1
2,5°
x 5
x 1
7.1 - Identifying the end limits
- The main power line must have a safety protection in accordance with the rules of the country of use.
- The power supply circuit must be equipped with an omnipolar cutting device with an openning gap of
3 mm minimum
. (EN60335-1 standard).
-
Switch off the installation during connection.
After connection: switch your installation on, check the direction of the operator rotation.
If the direction is not the desired one, disconnect power and invert the
brown
and
black
wires (230V power) or the
red
and
black
wires
(120V power).
- A "dead man" type control can be done only by use of
an unstable switch.
a -
Sliding end limits box cover
b & c -
Removable memory rings.
d & e -
Rotary adjusting wheels.
f & g -
Electric switches.
h -
Motor crown.
i -
Guiding blades.
7.2 - Adjustment
- Down end limit:
1 - Put electrically the shutter to the DOWN wished position.
2 - Remove the memory ring of the right side
(c)
.
3 - Turn the right adjusting ring
(e)
in the
“-”
direction until to activate the switch
(g)
.
- Up end limit:
1 - Put electrically the shutter to the UP wished position. (noise of the blades
i
)
2 - Move the shutter down up to the floor.
3 - Remove the memory ring of the left side
(b)
.
4 - Turn the left adjusting ring
(d) 2 turns
in the
“-”
direction
(tip: mark the wheel with a pencil).
- Move the shutter up and down to check the end limits positions. If necessary, turn the adjusting
wheels in the
“+”
direction to increase shutter travel or in the
“-”
direction to decrease shutter travel.
a
h
7.3
CBL Z 3x12 screw
5/5
Use and maintenance
8
The apron must be attached securely to the tube:
- If there is a curved plate, the links must be screwed to the curved plate and/or the motor
- If there is no curved plate, one of the links, or the 1st blade, must be screwed to the motor crown.
- Instructions for use: refer to the command point manuals and the clutch system manual.
- The motor does not require any maintenance operations.
Problems
Possible causes
Solutions
The motorised product is not working.
The motor is thermal.
Wait until the motor cools down.
The motorised product is running without
driving the curtain.
The clutch system is active.
Check that the clutch cable is not wound up or
that the clutch lever is deactivated.
EN
L
N
PE
4
Quick connector without screw
1
2
3
OK
30 N.m
±3
8 mm
30 N.m
±3
8 mm
CHC M10 ZnBl
JZC10 ZnBl
2 mm
max.
Connection diagram
(all Centris range)
5