TROUBLESHOOTING
Simtronics shall do all service and repairs. Troubleshooting ashould be performed by the
used as described below.
The detector can also give fault messages if the mounting brackets are not sufficiently
stable over time, for example with temperature changes or passing trucks resulting in the
GD1 coming temporarily out of alignment. Before troubleshooting is commenced the
rigidity of the mounting structure should be checked.
The most common issues are the following:
•
Misinterpretation of ppm*m as ppm. Described in section 10.4.
•
Poor alignment. Please be aware that it is the absolute transmission that should be
optimized, not the relative transmission (section 3.3).
•
Interference from a second transmitter as described in section 6.3.
Troubleshooting should always start by inspecting the detector’s lens
es for contamination
and/or defects. The following list may be helpful:
Issue
Possible source of
problem
Suggested correction
Clean optics
warning
(3 mA)
Dirt on lens.
Clean optics (see section 5.2).
Detector out of
alignment.
Realign detector (see chapter 0).
Beam block
(2 mA)
Dirt on lens.
Clean optics (see section 5.2).
Detector out of
alignment.
Realign detector (see chapter 0).
Objects that block the
measuring path.
Remove objects that block.
Detector in alignment
or service mode
Reboot detector by Service Interface
(Ethernet), HART®, or by
cutting/reconnecting power.
Fault
(1 mA)
Check error code in
the Service interface
Status screen.
See section 0 for a description and
suggestion on how to solve the issue.
No Power
(0 mA)
No power to the
detector.
Verify with multi meter in the Junction box
that detector has power.
Check both detector and system cable
wires on terminal 1 and 2 in the junction
box.
No wireless or
cable Ethernet
connection
Not connected to
network
Make sure your browser is connected to
the GD1 wireless network.
Loose connector
Check that the terminal adapter is securely
connected to terminals 3
–
6
Summary of Contents for GD1 MK3
Page 1: ...P N 850 816926 EN Rev6 Operating Manual Simtronics GD1 MK3 Toxic Open Path Gas Detector...
Page 8: ...GD1 Page 8 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 20: ...GD1 Page 20 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 42: ...GD1 Page 42 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 54: ...GD1 Page 54 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 58: ...GD1 Page 58 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 70: ...GD1 Page 70 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 72: ...GD1 Page 72 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 73: ...GD1 Page 73 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 74: ...GD1 Page 74 of 76 850 816926 EN R06 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 75: ...GD1 Page 75 of 76 850 816926 EN R06 EU DECLARATION OF CONFORMITY...