EQ44/54 SETUP menu
Chapter 10-5
10.3 Speed alarm, units & language
MENU
Call up the menu bar, and...
7,2
load Speed alarm, units & language display
Setup for speed:
Speed alarm maximum: 000.0kn OFF
Speed alarm minimum: 000.0kn OFF
Setup for units:
Depth/altitude in: METERS
Distance in: NAUTICAL MILES
Speed in: KNOTS
Temperature in: DEGREE CELCIUS
Software version: EQ44/54 2.20
AT44 version: HW rev.: 0,SW:- 2.00
PAGE rotation interval: 05 sec.
Display text in: English GB
MENU
Exit Accept
ENT
Scroll up/down to go to the function you wish to change
0-9
Key in new values, or...
+/-
Toggle between available values
ENT
Confirm changes, or...
MENU
exit function without making any changes
Speed alarm
- can be set to maximum and/or minimum cruising
speed. This may be handy for trawl fishing, entering harbors with
speed limits, etc.
Press [CLR] to reset an alarm - this applies to all activated alarms in
the system.
Depth altitude in
- can be set to meters (m), feet (ft), fathoms (fm) or
Italian unit: Passi braccio (Pb).
Summary of Contents for EQ44
Page 1: ...M A N U A L Simrad EQ44 54 Echosounder 183 3403 102 English 05082 20...
Page 2: ......
Page 6: ...Table of contents EQ44 54 Echosounder...
Page 12: ...Chapter 1 6 EQ44 54 Introduction and safety summary...
Page 26: ...Chapter 3 6 EQ44 54 Echosounder operation...
Page 68: ...Chapter 10 18 EQ44 54 SETUP menu...
Page 70: ...Chapter 11 2 EQ44 54 Installation and service Other important settings...
Page 76: ...AT44 Chapter 11 8 EQ44 54 Installation and service 11 5 Electrical connections...
Page 77: ...EQ44 54 Installation and service Chapter 11 9...
Page 97: ...EQ44 54 Echosounder Index...