4010 Operator Control Summary 

 

Extensive Feature List.

 The  4010 Fire Alarm Control 

Panel provides access to an extensive feature list that 
includes: 

 

Providing easy and powerful operator information with 
a logical, menu-driven display 

 

Extensive and automatic diagnostics for maintenance 
reduction 

 

History Logs available from the LCD or capable of 
(optionally) being printed 

 

Software Verification, allowing detailed logic 
programming simulation to be conducted without 
activating connected outputs 

 

Control Panel (or service PC) label editing 

 

Password access control 

 

Auto Program Quick Configuration (Quick-CFIG) of 
connected modules and IDNet devices for general alarm 
operation to quickly get the system up and running 

 

 

4010 Display Panel and Diagnostic Mode 

 

Convenient Status Information.

 With the locking 

door closed, a window allows viewing of the status 
display. The 4010 status panel provides a two line by 40 
character, super-twist LCD information display and eight 
status LED indicators as shown in the illustration below.  

From this display, the LED indicators will describe the 
general category of activity being displayed with the LCD 
providing more detail. For the authorized user, unlocking 
the door will provide access to the control switches and 
allow further inquiry by scrolling the display for 
additional detail. (Refer to control panel functional 
illustration below.) 

WALKTEST Diagnostic Operation Mode.

 The 

WALKTEST process allows a single person to perform 
system test. The system records test inputs such as 
intentional alarms or trouble and either logs the response 
(silent WALKTEST operation) or outputs a brief, 
recognizable audible notification signal (audible 
WALKTEST operation). 

 2 

S4010-0001-14 

 

6/2014

SUPV

ACK

SYSTEM

SUPERVISORY

ALARM

ACK

FIRE

ALARM

TROUBLE

ACK

SYSTEM

TROUBLE

ALARM

SILENCE

ALARM

SILENCED

SYSTEM

RESET

AC

POWER

MENU

FUNCTION

ENTER

DISABLE

ENABLE

EXIT

CLEAR

PREVIOUS

NEXT

FIVE STATUS INDICATOR LEDs provide system status indications in 
addition to LCD information, LEDs flash to indicate the condition and 
then when acknowledged, remain on until reset

2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal 
operating conditions, provides up to 40 characters for custom label information

FIRST ALARM DISPLAY: Operation can be selected for maintained display of first 
alarm until acknowledged

THREE PROGRAMMABLE LEDs 
provide custom labeling (labels insert into 
a pocket), the top two LEDs are 
selectable as red or yellow, the bottom 
LED is selectable as green or yellow

CONTROL 

PANEL VIEW with 

4010 door closed

ALARM ACK acknowledges a Fire Alarm condition, 
logs the acknowledge and silences the operator 
panel and all annunciator tone-alerts

SUPV ACK acknowledges system supervisory 
conditions, logs the acknowledge, and silences the 
operator panel and all annunciator tone-alerts

TROUBLE ACK acknowledges system troubles, 
logs the acknowledge, and silences the operator 
panel and all annunciator tone-alerts

ALARM SILENCE causes audible notification appliances 
to be silenced, used after evacuation is complete and 
while alarm source is being investigated

NINE EXTENDED FUNCTION KEYS (accessible with door 
open) select and scroll through display prompts for locating 
additional system information, performing maintenance 
functions, or for front panel programming

SYSTEM RESET restores 
control panel to normal when 
all alarmed inputs are 
returned to normal

 

 

 Extended Operator Control Panel Functions 

Summary of Contents for TrueAlarm

Page 1: ...with standard door Description TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control When equipped with TrueAlarm analog sensing for smoke and he...

Page 2: ...recognizable audible notification signal audible WALKTEST operation 2 S4010 0001 14 6 2014 SUPV ACK SYSTEM SUPERVISORY ALARM ACK FIRE ALARM TROUBLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENCED SYS...

Page 3: ...ent levels of smoke obscuration in percent or for specific heat detection levels In order to evaluate whether the sensitivity should be revised the peak value is stored in memory and can be easily rea...

Page 4: ...ENCED SYSTEM RES ET AC POWER Local maintenance computer One connection type per 4010 selected by module choice max wiring distance is 300 ft 91 m 9600 baud RS 232 Connection Options refer to module s...

Page 5: ...ork Interface Modular Media Available for wired connections or fiber optic Require separate media modules May be both wired both fiber optic or one of each Optional Expansion Slot Modules Cont d Netwo...

Page 6: ...liances rated 2 A for Regulated 24 DC appliance power 4010 9823 240 VAC input Optional Features select as indicated 4010 9825 24 VDC Expansion Power Distribution Module provides two additional termina...

Page 7: ...each maximum up to 33 synchronized strobes maximum per NAC Current Ratings for Optional Modules and Remote LCD Annunciator Model Module Supervisory Current Alarm Current 4010 9810 DACT Common Event Re...

Page 8: ...1 2 368 mm WATERFLOW LEFT WING GROUND FAULT WATERFLOW RIGHT WING SUPV ACK SYSTEM SUPER VISORY ALARM ACK FIR E ALARM TROU BLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENC ED SYSTEM RESET AC POWER MENU...