4010 Operator Control Summary
Extensive Feature List.
The 4010 Fire Alarm Control
Panel provides access to an extensive feature list that
includes:
Providing easy and powerful operator information with
a logical, menu-driven display
Extensive and automatic diagnostics for maintenance
reduction
History Logs available from the LCD or capable of
(optionally) being printed
Software Verification, allowing detailed logic
programming simulation to be conducted without
activating connected outputs
Control Panel (or service PC) label editing
Password access control
Auto Program Quick Configuration (Quick-CFIG) of
connected modules and IDNet devices for general alarm
operation to quickly get the system up and running
4010 Display Panel and Diagnostic Mode
Convenient Status Information.
With the locking
door closed, a window allows viewing of the status
display. The 4010 status panel provides a two line by 40
character, super-twist LCD information display and eight
status LED indicators as shown in the illustration below.
From this display, the LED indicators will describe the
general category of activity being displayed with the LCD
providing more detail. For the authorized user, unlocking
the door will provide access to the control switches and
allow further inquiry by scrolling the display for
additional detail. (Refer to control panel functional
illustration below.)
WALKTEST Diagnostic Operation Mode.
The
WALKTEST process allows a single person to perform
system test. The system records test inputs such as
intentional alarms or trouble and either logs the response
(silent WALKTEST operation) or outputs a brief,
recognizable audible notification signal (audible
WALKTEST operation).
2
S4010-0001-14
6/2014
SUPV
ACK
SYSTEM
SUPERVISORY
ALARM
ACK
FIRE
ALARM
TROUBLE
ACK
SYSTEM
TROUBLE
ALARM
SILENCE
ALARM
SILENCED
SYSTEM
RESET
AC
POWER
MENU
FUNCTION
ENTER
DISABLE
ENABLE
EXIT
CLEAR
PREVIOUS
NEXT
FIVE STATUS INDICATOR LEDs provide system status indications in
addition to LCD information, LEDs flash to indicate the condition and
then when acknowledged, remain on until reset
2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal
operating conditions, provides up to 40 characters for custom label information
FIRST ALARM DISPLAY: Operation can be selected for maintained display of first
alarm until acknowledged
THREE PROGRAMMABLE LEDs
provide custom labeling (labels insert into
a pocket), the top two LEDs are
selectable as red or yellow, the bottom
LED is selectable as green or yellow
CONTROL
PANEL VIEW with
4010 door closed
ALARM ACK acknowledges a Fire Alarm condition,
logs the acknowledge and silences the operator
panel and all annunciator tone-alerts
SUPV ACK acknowledges system supervisory
conditions, logs the acknowledge, and silences the
operator panel and all annunciator tone-alerts
TROUBLE ACK acknowledges system troubles,
logs the acknowledge, and silences the operator
panel and all annunciator tone-alerts
ALARM SILENCE causes audible notification appliances
to be silenced, used after evacuation is complete and
while alarm source is being investigated
NINE EXTENDED FUNCTION KEYS (accessible with door
open) select and scroll through display prompts for locating
additional system information, performing maintenance
functions, or for front panel programming
SYSTEM RESET restores
control panel to normal when
all alarmed inputs are
returned to normal
Extended Operator Control Panel Functions