Features 

 

Standard features include: 

 

Up to 250 addressable TrueAlarm sensor or addressable 
device points using IDNet communications that operate 

with either shielded or unshielded 

twisted pair wiring 

 

Four, 2 A notification appliance circuits (NACs) with 
solid state current protection 

 

Power supply/battery charger with 4 A available for 
NACs and auxiliary power 

 

Internal event reporting DACT module (standard on 
models 4010-9101, 4010-9102, & 4010-9150) 

 

UL listed to Standard 864 

Installation convenience features: 

 

Power-limited design provides electronic modules on 
a one-piece chassis with up-front terminal blocks for 
wiring access 

 

Compact NEMA 1 rated cabinet is available in beige 
or red and can be pre-shipped for early installation 

Setup, programming, and maintenance features: 

 

Device level ground fault search, locate, and isolate 

 

Auto Program

 for general alarm operation 

 

TrueAlarm individual analog sensing with front panel 
information and selection access 

 

“Dirty” TrueAlarm sensor maintenance alerts, service 
and status reports including “almost dirty”  

 

Default TrueAlarm sensor device type operation 

 

TrueAlarm sensor peak value performance report 

 

Duplicate address error detection 

 

Front panel or PC programming 

 

WALKTEST silent or audible system test 

 

Software verification simulation mode 

Supports the following IDNet devices: 

 

Addressable manual stations; TrueAlarm sensor bases, 
duct housings, and isolator bases 

 

Quad-state zone adapter modules (ZAMs) for initiating 
device monitoring 

 

Quad-state line powered individual addressable modules 
(IAMs) for initiating device monitoring and relay control 

 

4009 IDNet NAC Extenders and accessories 

Available option modules include: 

 

Door mounted 24 LED annunciator (std. on ULC models) 

 

Network connection, or Point Reporting DACT 

 

Class A, NAC adapter module 

 

RS-232 ports for printer and maintenance PC 

 

Expansion power supply; Auxiliary Relay Module or 
City Interface 

 

Equipment for Suppression Release Applications 
(refer to data sheet S4010-0003) 

Compatible with Simplex

®

 auxiliary panels: 

 

4003 Voice Control Panel 

 

4081 Battery Cabinet with charger for 50 Ah batteries 

 

4010 Fire Alarm Control Panel (with standard door) 

Description 

 

TrueAlarm fire alarm control panels

 have the ability 

to provide location accuracy for monitoring and control. 
When equipped with TrueAlarm analog sensing for smoke 
and heat detection, the processing power of the control 
panel also has the ability to analyze conditions at each 
location to provide accurate detection with significantly 
reduced maintenance costs. 

The 4010 TrueAlarm Fire Alarm Control Panel has been 
specifically designed to provide addressable operation and 
analog detection in a cost-effective package for application 
sizes that previously were considered only appropriate for 
conventional zoned monitoring.  

Installation and Service Ease.

 The 4010 mounts on a 

single chassis for quick installation and removal. Terminal 
blocks are large and up-front for easy access and inspection. 
Optional modules are easily and quickly installed, and 
programmed as required. 

The 4010 cabinet provides convenient stud markers for 
drywall thickness and nail-hole knockouts for quicker 
mounting. Smooth cabinet surfaces are provided for locally 
cutting conduit entrance holes exactly where required. 4010 
cabinets and electronics can be ordered separately, allowing 
early cabinet installation. 

Ground Fault Assistance.

 Ground fault problems often 

occur during installation. The 4010 provides isolating 
circuitry, control of isolator bases, and software-controlled 
sequencing to isolate ground faults to specific identified 
locations. This assistance helps the installer to accurately 
locate the wiring problem for quicker repair. 

 

*   Refer to page 6 for listing details. This product has been approved by the California State 

Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. 

See CSFM Listing 7170-0026:226 for allowable values and/or conditions concerning 

material presented in this document. Accepted for use – City of New York Department of 

Buildings – MEA35-93E. Additional listings may be applicable; contact your local Simplex 

product supplier for the latest status. Listings and approvals under Simplex Time Recorder 

Co. are the property of Tyco Fire Protection Products. 

 

 

TrueAlarm Fire Alarm Controls  

UL, ULC, CSFM Listed; FM Approved;

 

 Model 4010 Fire Alarm Control Panel for TrueAlarm

 

MEA (NYC) Acceptance*

 

Analog Sensors and IDNet Addressable Devices

 

 

 

S4010-0001-14  6/2014

 

 

Summary of Contents for TrueAlarm

Page 1: ...with standard door Description TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control When equipped with TrueAlarm analog sensing for smoke and he...

Page 2: ...recognizable audible notification signal audible WALKTEST operation 2 S4010 0001 14 6 2014 SUPV ACK SYSTEM SUPERVISORY ALARM ACK FIRE ALARM TROUBLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENCED SYS...

Page 3: ...ent levels of smoke obscuration in percent or for specific heat detection levels In order to evaluate whether the sensitivity should be revised the peak value is stored in memory and can be easily rea...

Page 4: ...ENCED SYSTEM RES ET AC POWER Local maintenance computer One connection type per 4010 selected by module choice max wiring distance is 300 ft 91 m 9600 baud RS 232 Connection Options refer to module s...

Page 5: ...ork Interface Modular Media Available for wired connections or fiber optic Require separate media modules May be both wired both fiber optic or one of each Optional Expansion Slot Modules Cont d Netwo...

Page 6: ...liances rated 2 A for Regulated 24 DC appliance power 4010 9823 240 VAC input Optional Features select as indicated 4010 9825 24 VDC Expansion Power Distribution Module provides two additional termina...

Page 7: ...each maximum up to 33 synchronized strobes maximum per NAC Current Ratings for Optional Modules and Remote LCD Annunciator Model Module Supervisory Current Alarm Current 4010 9810 DACT Common Event Re...

Page 8: ...1 2 368 mm WATERFLOW LEFT WING GROUND FAULT WATERFLOW RIGHT WING SUPV ACK SYSTEM SUPER VISORY ALARM ACK FIR E ALARM TROU BLE ACK SYSTEM TROUBLE ALARM SILENCE ALARM SILENC ED SYSTEM RESET AC POWER MENU...

Reviews: