8 System 3060 battery replacement
8.1 General instructions
Only trained personnel may replace the batteries.
You must wear clean gloves made of cloth and free of fat or grease when
replacing the batteries to prevent the batteries being contaminated by
fingerprints. Fingerprints on batteries may reduce battery life considerably.
Only use batteries which have been approved by SimonsVoss.
NOTE
You may cause damage to the Locking Cylinder 3061 if you reverse the po-
larity. The batteries used in this device may pose a fire or burn hazard if
handled incorrectly. Do not recharge, open or burn batteries, or heat them
to over 100° C.
NOTE
Dispose of lithium batteries properly immediately after they have dis-
charged. Store them out of children's reach; do not open and do not throw
into a fire. Always replace both batteries when changing batteries. Please
note safety instructions.
The locking cylinder retains its status, programming and saved protocols
even without power supply.
8.2 Battery life
Battery life is different for each locking cylinder version as power
consumption varies when the cylinder is activated or a data connection is
established.
VERSION
BATTERY LIFE
NUMBER OF AC-
TIVATIONS
NUMBER OF
BATTERIES
Standard cylinder
and versions
Up to 10 years
Up to 300,000
2
WN (LNI /
LockNode)
Up to 5 years
Up to 150,000
2
The specified battery life is for guidance only. A battery warning is not
emitted when the aforementioned battery life expires, but is based on the
measured battery status instead.
Digital Locking Cylinder 3061
(Manual)
8. System 3060 battery replacement
38 / 54