Simer SMART GEYSER 2330-03 Owner'S Manual Download Page 2

Safety

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

GENERAL SAFETY

Electrically powered utility pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris, flooding
that exceeds the pump’s capacity, electrical or mechani-
cal failure in the pump, etc.) may prevent your pump
from functioning normally. To prevent possible water
damage due to flooding, consult your retailer about a
secondary AC pump, a DC backup pump, and/or a high
water alarm. See the “Troubleshooting Chart” in this
manual for information about common pump problems
and remedies. For more information, see your retailer or
call Simer customer service at 1-800-468-7867.

1. Know the pump application, limitations, and poten-

tial hazards.

Do not use in explosive atmospheres.

Pump water only with this pump. Failure to follow
this warning can result in personal injury and/or
property damage.

2. Make certain power source conforms to requirements

of your equipment.

3. Disconnect power before servicing.

4. Release all pressure within system before servicing

any component.

5. Drain all water from system before servicing.

6. Secure discharge line before starting pump. An unse-

cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.

7. Check hoses for weak or worn condition before each

use, making certain all connections are secure.

8. Periodically inspect pump and system components.

Keep pump and system free of debris and foreign
objects. Perform routine maintenance as required.

9. Provide means of pressure relief on pumps whose dis-

charge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and properly

lighted – replace all unused tools and equipment.

c. Keep visitors at a safe distance from the work

area.

d. Make workshop child-proof – with padlocks, mas-

ter switches, and by removing starter keys.

11. When wiring an electrically driven pump, follow all

electrical and safety codes, as well as most recent
National Electrical Code (NEC) and Occupational
Safety and Health Act (OSHA).

Pump motor is equipped with an auto-

matic resetting thermal protector and may restart
unexpectedly.

12.

Risk of electric shock.

This equipment is

only for use on 115 volt (single phase) and is
equipped with an approved 3-conductor cord and 3-
prong, grounding-type plug.

To reduce risk of electric shock, be cer-

tain that it is connected to properly grounded,
grounding-type receptacle.

Where a 2-prong wall receptacle is encountered, it
must be replaced with properly grounded 3-prong
receptacle installed in accordance with the National
Electrical Code and local codes and ordinances.

13. All wiring should be performed by a qualified 

electrician.

14. Protect electrical cord from sharp objects, hot sur-

faces, oil, and chemicals. Avoid kinking cord. Replace
or repair damaged or worn cords immediately.

15. Use wire of adequate size to minimize voltage drop

at motor. Refer to most recent National Electrical
Code.

16. Do not touch an operating motor. Modern motors can

operate at high temperatures.

SPECIFICATIONS

Power supply required ................................115V, 60 HZ.

Liquid Temp. Range ..............................Max. 77°F (25°C)

Operation Position ...............................................Vertical

Individual Branch Circuit Required  ....................15 Amp

Operating Depth

Beginning min.........................3/4"

(water level)

Ending max. ............................1/4"

Discharge ...............................................1" NPT (25 mm)

DESCRIPTION

The submersible pump is designed for water removal in
home applications. Pump can be used for emergency
service and dewatering. Unit is constructed of hi-impact
corrosion resistant plastic. Screened inlet prevents large
solids from entering pump.

NOTICE:

This unit is not designed for applications involv-

ing salt water or brine! Use with salt water or brine will
void warranty.

PERFORMANCE

GPH (LPH) AT TOTAL FEET (M)

3'

5'

10'

15'

18'

20'

22'

(0.91)

(1.52)

(3.05)

(4.57)

(5.49)

(6.09)

(6.70)

1600 gal 1524 gal 1260 gal 924 gal

648 gal

372 gal

0 gal

(6 057 L) (5 769 L) (4 770 L) (3 498 L) (2 453 L) (1 408 L)

(0 L)

Summary of Contents for SMART GEYSER 2330-03

Page 1: ...8 7867 English Pages 2 4 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 5 7 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 8 10 2005 SIM566 Rev 6 13 07 3671 0300 INT SIM 293 Wrig...

Page 2: ...t a safe distance from the work area d Make workshop child proof with padlocks mas ter switches and by removing starter keys 11 When wiring an electrically driven pump follow all electrical and safety codes as well as most recent National Electrical Code NEC and Occupational Safety and Health Act OSHA Pump motor is equipped with an auto matic resetting thermal protector and may restart unexpectedl...

Page 3: ...rts the pump every 2 1 2 minutes and causes it to run for 5 seconds If it senses that there is no water to the pump it stops If it senses water it continues to run until the water is pumped down to 1 4 deep and then it stops It then goes into a 7 minute quick detection cycle starting 4 times the first minute twice the second minute and once a minute for the next 5 minutes If by the last check it h...

Page 4: ...tage under recommended minimum check size of wiring from main switch on property If OK contact power company Defective motor Replace pump Impeller Remove screen locate source of binding Pump operates Low line voltage Use only 14 gauge or larger extension cords Use short extension cords but delivers little when necessary or no water Something caught in impeller Clean out impeller Small diameter gar...

Page 5: ...e b Maintenir la zone de travail propre en ordre et correctement éclairée Ranger tous les outils et matériels non utilisés c Maintenir les visiteurs à une distance prudente de la zone de travail d Veiller à ce que les enfants soient écartés des dangers de l atelier avec des cadenas et des interrupteurs maîtres et en ôtant les clés de démarrage 11 Pendant le câblage d une pompe à fonctionnement éle...

Page 6: ... jusqu à une profondeur de 1 4 de pouce puis il arrêtera la pompe La pompe passe ensuite dans un cycle de détection rapide de 7 minutes qui se répète 4 fois lors de la première munute deux fois lors de la deuxième minute et une fois para minute pour les 5 prochaines minutes Si lors de la dernière vérification la pompe ne détecte pas d eau elle reprend son cycle normal c est à dire qu elle fonction...

Page 7: ... que des cordons prolongateurs de calibre 14 ou plus gros Dans la fonctionne mais mesure du possible utiliser des cordons prolongateurs de courte longueur elle déverse peu Quelque chose obstrue Nettoyer la roue hélice ou pas d eau la roue hélice Tuyau d arrosage de petit Utiliser un tuyau souple de 1 pouce ou un tuyau d arrosage de plus grand diamètre ou conduite de diamètre Éliminer toute longueu...

Page 8: ...nada Aparte todas las herramientas y equipos que no esté usando c No deje que se acerquen otras personas a la zona de trabajo d Asegure el taller a prueba de niños Use candados interruptores generales y saque las llaves de arranque 11 Cuando conecte una bomba de impulsión eléctrica respete todos los códigos eléctricos y de seguridad así como otros más recientes como el Código Eléctrico Nacional NE...

Page 9: ... bomba se detiene Si detecta agua continúa funcionando hasta que haya bombeado agua hasta una profundidad de 1 4 y luego se detiene Luego pasa a un ciclo de detección rápida de 7 minutos comenzando 4 veces durante el primer minuto dos veces durante el segundo minuto y una vez por minuto durante los próximos 5 minutos Si cuando llega a la última verificación aún no ha detectado agua volverá a pasar...

Page 10: ...e cables de extensión de calibre 14 Use cables de extensión funcionapero cortos cuando sea necesario no suministra Objeto atascado en el rodete Limpie el impulsor agua o muy Manguera de jardín de Use una manguera de jardín de mayor diámetro o un tubo flexible de 1 poca agua diámetro chico o línea de Deseche el exceso de manguera Las mangueras cortas funcionan mejor descarga larga Examine la válvul...

Page 11: ...garantit à l acheteur utilisateur initial de ses produits Acheteur contre tout défaut de fabrication et de matériaux Tout produit reconnu défectueux dans les douze 12 mois qui suivent la date d achat d origine sera remplacé ou réparé à la discrétion de SIMER selon les conditions stipulées ci dessous La preuve d achat est exigée pour déterminer l admissibilité à la garantie Exceptions à la garantie...

Page 12: ...s por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedidos de servicio bajo los términos de esta garantía serán efectuados mediante la devolución del producto defectuoso al Vendedor o a SIMER tan pronto como sea posible des pués de localizado cualquier supuesto defecto SIMER tomará luego acción correctiva tan pronto c...