background image

For parts or assistance, call Simer Customer Service at 

1-800-468-7867

Safety

2

SAFETY INFORMATION

Use this pump only on a 115

volt circuit. Pump is equipped
with an approved 3-conduc-

tor cord and 3-prong, grounding-type
plug. To reduce the risk of electric shock,
connect it to a properly grounded,
grounding-type receptacle.

If circuit has a 2-prong receptacle, replace
it with a properly grounded 3-prong recep-
tacle installed in accordance with the
National Electrical Code and local codes
and ordinances. 
Any extension cord used must be outdoor
grade, gauge 16 AWG or heavier, and not
more than 25’ long.

Risk of fire or explosion if

used to pump flammable liquids or if used
in explosive atmospheres.

Pump water

only with this pump. Pump is designed 
to pump water at temperatures between
32°-77° F (0°-25° C) only.

Risk of electrical shock. Do

not allow the motor to get wet! 

Risk of burns.

During nor-

mal operation, motor case may heat
enough to burn you. Do not touch motor
when it is hot.
Do not operate the pump continuously at a
discharge pressure of more than 12 psi 
(83 kPa) or discharge lift of more than 
28’ (8.5 M), as the motor will exceed the
normal safe operating temperature and
may heat to 180° - 190° F (82° C - 88° C).

NOTICE:

This unit is not designed for appli-

cations involving salt water or brine! Use
with salt water or brine will void warranty.

Hazardous
voltage

SIMER warrants to the original consumer purchaser

(“Purchaser”) of its products that they are free from defects in

material or workmanship.

If within twelve (12) months from the date of the original

consumer purchase any such product shall prove to be

defective, it shall be repaired or replaced at SIMER’s option,

subject to the terms and conditions set forth below. Your orig-

inal receipt of purchase is required to determine warranty eli-

gibility.

Exceptions to the Twelve (12) Month Warranty
Ninety (90) Day Warranty:

If within ninety (90) days from original consumer purchase

any Drill Pump or MiniVac Pump shall prove to be defective,

it shall be replaced, subject to the terms set forth below.

Two (2) Year Warranty:

If within two (2) years from original consumer purchase, any

1/3 HP Submersible Sump Pump, or Models 2330, 2300 or

A5500,  shall prove to be defective, it shall be repaired or

replaced at SIMER’s option, subject to the terms and condi-

tions set forth below.

Three (3) Year Warranty:

If within three (3) years from original consumer purchase any

4” Submersible Well Pump, 1/2 HP Submersible Sump

Pump, or Booster Pump Model 3075SS shall prove to be

defective, it shall be repaired or replaced at SIMER’s option,

subject to the terms and conditions set forth below.

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any

Pre-Charge water system tank shall prove to be defective, it

shall be repaired or replaced at SIMER’s option, subject to

the terms and conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to

replace product covered by this warranty. This warranty shall

not apply to acts of God, nor shall it apply to products which,

in the sole judgement of SIMER, have been subject to negli-

gence, abuse, accident, misapplication, tampering, alteration;

nor due to improper installation, operation, maintenance or

storage; nor to other than normal application, use or service,

including but not limited to, operational failures caused by cor-

rosion, rust or other foreign materials in the system, or opera-

tion at pressures in excess of recommended maximums.

Requests for service under this warranty shall be made by

returning the defective product to the Retail outlet or to SIMER

as soon as possible after the discovery of any alleged defect.

SIMER will subsequently take corrective action as promptly as

reasonably possible. No requests for service under this war-

ranty will be accepted if received more than 30 days after the

term of the warranty.

This warranty sets forth SIMER’s sole obligation and purchas-

er’s exclusive remedy for defective products.

SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN

LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED

WARRANTIES, INCLUDING BUT NOT LIMITED TO THE

IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT-

NESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND

BEYOND THE DURATION OF THE APPLICABLE EXPRESS

WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of inci-

dental or consequential damages or limitations on how long

an implied warranty lasts, so the above limitations or exclu-

sions may not apply to you. This warranty gives you specific

legal rights and you may also have other rights which vary

from state to state.

Simer Limited Warranty

SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115

Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351

EMail: [email protected] • Web: http://www.simerpumps.com

Summary of Contents for MINI-VAC M40-04

Page 1: ...installation or maintenance assistance Call 1 800 468 7867 English Pages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Compo...

Page 2: ...hin three 3 years from original consumer purchase any 4 Submersible Well Pump 1 2 HP Submersible Sump Pump or Booster Pump Model 3075SS shall prove to be defective it shall be repaired or replaced at...

Page 3: ...art to move water in 30 seconds or less recheck the installation and plumbing Mount the pump solidly on a stable platform USE 1 2 HOSE OR LARGER Use a reinforced hose on the inlet The pump should be l...

Page 4: ...tlet hose is not under water If the outlet is under water the pump may not work Plug the cord into a 3 wire 115 volt 60 Hz grounded A C outlet You should get water in 30 seconds or less If not add mor...

Page 5: ...will automatically warning and thermal overload restart has tripped Discharge hose too long Use shorter hose or reduce lift or discharge lift higher than 28 Pump Won t Prime Pump body not oiled Add o...

Page 6: ...L ScoopTM No FP000349A includes the Pud L ScoopTM and a 6 garden hose with washer Key Part No Description Qty 1 10 32x1 3 4 Phil Hd Screw 2 2 End Cover Wear Plate 1 3 O Ring 1 4 Impeller 1 5 Insert 1...

Page 7: ...e au choix de SIMER conform ment aux termes et conditions stipul s ci dessous Garantie de trois 3 ans Si dans les trois 3 ans compter de la date d achat par le con sommateur d origine une pompe de pui...

Page 8: ...UN TUYAU SOUPLE DE 1 3 CM 1 2 PO OU PLUS GROS Utiliser un tuyau souple renforc sur le c t admission Cette pompe doit tre install e moins de 3 m tres 10 pieds au dessus de la source d eau et moins de...

Page 9: ...s fonctionner Brancher le c ble la prise 3 fils m talliques de 115 volts c a et 60 Hz mise la terre La pompe devra d biter dans les 30 secon des Si non rajouter de l huile et r p ter le processus Si l...

Page 10: ...ourt ou abaisser la hauteur est trop long ou la hauteur de refoulement est sup rieure 28 pieds La pompe ne Le corps de la pompe Ajouter de l huile par l orifice Se reporter la page 8 s amorce pas n es...

Page 11: ...de chacune des R f 3 4 et 6 Les n cessaires de balais n FP003415S comprend une paire de balais de ressorts et de capuchons rempla ables Ref 10 Le Pud L ScoopMC n FP000349A comprend le Pud L ScoopMC e...

Page 12: ...nos y a las condiciones indicadas a continuaci n Garant a de tres 3 a os Si se comprueba que una Bomba Sumergible de Pozo de 4 o una Bomba Sumergible de Sumidero de 1 2 CV tienen defectos dentro de lo...

Page 13: ...bomba en forma segura sobre una plataforma estable USE UNA MANGUERA DE 1 2 O MAYOR Use una manguera reforzada en la admisi n La bomba debe estar a menos de 10 pies por encima y a menos de 25 pies a un...

Page 14: ...rriente trifilar de CA 115 voltios 60 Hz conectado a tierra Deber obtener agua en 30 segundos o menos De lo contrario agregue m s aceite y repita el proceso Si su bomba no ceba en la segunda tentativa...

Page 15: ...altura es demasiado larga o la altura de descarga es mayor que 28 pies La bomba no ceba La unidad de la bomba no Agregar aceite por el orificio de admisi n consultar est lubricada la P gina 13 La man...

Page 16: ...3 4 y 6 Juego de escobillas No FP003415S incluye un par de escobillas resortes y casquetes reemplazables Clave No 10 Pud L ScoopMC placa colectora No FP000349A incluye el Pud L ScoopMC y una manguera...

Reviews: