REGULATION OF THE WATER TEMPERATU-
RE FOR HEATING (fig. 26)
To.set.the.temperature.of.the.water.for.hea-
ting,. press. the. key
.
.
of. the. controls. (2)..
The.first.time.the.key.is.pressed,.the.SET.of.
heating.circuit.1.is.selected..
The.second.time.it.is.pressed,.the.SET.of.he-
ating.circuit.2.is.selected..The.display.will.be.
as. shown. in. the. figure.. Change. the. values.
with.the.key
.
5
3
1
2
4
.
and.
5
3
1
2
4
.
.
Standard.visualisation.will.return.to.the.di-
splay.by.pressing.the.key.
.
again,.or.after.
10.seconds.if.no.key.is.pressed.
Regulation of the external sensor (fig.
26/a)
If.an.external.sensor.is.installed,.the.value.
of. the. output. temperature. is. automatically.
chosen.by.the.system,.which.quickly.adjusts.
the.environmental.temperature.on.the.basis.
of.the.external.temperature..If.you.wish.to.
change. the. value. of. the. temperature,. in-
creasing. or. decreasing. that. calculated. au-
tomatically.by.the.electronic.card,.proceed.
as. indicated. in. the. preceding. paragraph..
The.level.of.various.correction.of.a.value.of.
temperature. proportional. calculated.. The.
display.will.be.as.shown.in.fig..26/a.
REGULATION OF THE D.H.W.
TEMPERATURE (fig. 27)
To. set. the. desired. temperature. D.H.W.,.
press.the.key
.
.
of.the.controls.(pos..2)..The.
display.will.be.as.shown.in.the.figure.
Change. the. values. with. the. key
.
5
3
1
2
4
.
and.
5
3
1
2
4
.The.display.will.return.to.the.standard.
visualisation.by.pressing.the.key
.
.
again,.
or.after.10.seconds.if.no.key.is.pressed.
TO SWITCH OFF THE BOILER (fig. 25)
In.the.case.of.a.short.absence,.press.the.key
.
of.the.controls.(pos..2)..The.display.will.
be.as.shown.in.the.figure.25..In.this.way,.le-
aving.the.electricity.and.the.fuel.supply.con-
nected,. the. boiler. is. protected. from. frost.
and.from.the.pump.becoming.blocked..If.the.
boiler.is.not.used.for.a.prolonged.period,.it.is.
advisable.to.disconnect.the.electricity.sup-
ply,.by.switching.off.the.main.switch.of.the.
system,.and.to.close.the.gas.tap.and,.if.low.
temperatures. are. expected,. to. completely.
empty. the. hydraulic. circuits. to. avoid. pipes.
being.broken.by.the.formation.of.ice.in.the.
pipes.
ANOMALIES AND SOLUTIONS
When. there. is. a. functioning. anomaly,. the.
display.shows.an.alarm.and.the.blue.lumi-
nous.bar.becomes.red..Descriptions.of.the.
anomalies.with.the.relative.alarms.and.so-
lutions.are.given.below:
–. ALL 01 (fig. 28)
.
Press.the.key
.
5
3
1
2
4
.
of.the.controls.(2).to.
re-start.the.boiler..
. If the anomaly persists, request the in-
tervention of qualified technical person-
nel.
–. ALL 02 (fig. 28/a)
.
If. the. water. pressure. detected. is. lower.
than.0.5.bar,.the.boiler.will.stop.and.the.
display.will.show.“ALL.02”..
. Bring.the.pressure.back.to.normal.by.ac-
ting.on.the.loading.knob..Lower.the.knob.
and. turn. it. anti-clockwise. to. open. until.
the. pressure. indicated. by. the. display. is.
between.1.and.1.5.bars.
. WHEN. FILLING. HAS. BEEN. COMPLE-
TED,. CLOSE. THE. KNOB. BY. TURNING. IT.
CLOCKWISE.
. If it is necessary to repeat the system
loading procedure, it is advisable to
contact qualified technical personnel to
check the seal of the heating system (to
check whether there are any leaks).
–. ALL 03/ALL 04/ALL 05
. Request assistance from qualified tech-
nical personnel.
–. ALL 06 (fig. 28/c)
. Press.the.key
.
5
3
1
2
4
.
of.the.controls.(2).to.
re-start.the.boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
–. ALL 07 (fig. 28/d)
. Press.the.key.
5
3
1
2
4
.of.the.controls.(2).to.
re-start.the.boiler.
. If the anomaly persists, request assi-
stance from qualified technical person-
90
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..26/a
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..27
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
APRE
Fig..28/a
OPEN
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..28
Fig..26
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Heating
circuit 2
Summary of Contents for Murelle 25 OF
Page 1: ...MURELLE 25 30 OF ErP Fonderie SIME S p A Cod 6322862A 03 2017 ES PT ENG...
Page 2: ......
Page 35: ......