Models MURELLE
25 OF ErP
30 OF ErP
Heat output
nominal (Pn max).
kW.
23.0.
27.0
Heat output
reduced (Pn min)
.
kW.
8.7
10.2
Heat input (*)
Nominal.(Qn.max.-.Qnw.max).
kW.
25.5
30.0
Reduced.(Qn.min.-.Qnw.min)
.
kW.
10.2
12.0
Thermal yield 100% useful
90.0.
90.0
Thermal yield useful at 30% of load
91.1.
91.5
Losses after shutdown to 50°C (EN 15502)
W.
152.
179.
.
Supply voltage
V-Hz.
230-50.
230-50
Adsorbed power consumption (Qn max - Qn min)
W
54.-.47.
54.-.47
Electrical protection grade
IP.
X4D
X4D
Energy efficiency
Seasonal.energy.efficiency.class.of.the.heating.system.
.
C.
C.
.
Seasonal.energy.efficiency.of.the.heating.system.
%.
78.
79
Sound.power.of.the.heating.system...........
dB.(A).
49.
49
D.H.W..energy.efficiency.class.
.
B.
B
D.H.W..energy.efficiency..
%.
78.
78
D.H.W..load.profile.declared.
.
XL.
XL
C.H. setting range.
°C.
20÷80.
20÷80
Water content boiler.
l.
7.1.
8.0
Maximum water head (PMS)
bar.(kPa).
3.(294).
3.(294)
Maximum temperature (T max)
°C.
85.
85
Expansion vessel capacity
l.
7.
8
Expansion vessel pressure
bar.(kPa).
1.(98).
1.(98)
D.H.W. setting range.
°C.
10÷65.
10÷65
D.H.W. flow rate (EN 13203).
l/min.
10.7.
12.7.
Continuous D.H.W. flow rate (∆t 30°C).
l/min.
10.9.
12.9
Minimum D.H.W. flow rate.
l/min.
2.4.
2.4
D.H.W pressure min/max (PMW).
bar.(kPa).
0.2/7.(19.6/686).
0.2/7.(19.6/686)
D.H.W. pressure min. nom. power
bar.(kPa).
0.5.(49).
0.65.(63.7)
Smokes temperature min/max.
°C.
88/122.
95/135
Smokes flow min/max.
g/s.
18/20.
18/20
CO
2
%.
5,2.
6,2
NOx measured
mg/kWh.
140.
138
PIN number
1312BU5345.
1312BU5345
Category
II2H3+.
II2H3+
Type of appliance
B11BS
.
B11BS
NOx emission class
.
.
3.(‹150.mg/kWh).
3.(‹150.mg/kWh)
Weight when empty
.
kg
30.
33
Main burner nozzle
Quantity.nozzles.
n°.
12.
14
G20.nozzle.diameter
.
mm.
1.30.
1.30
G30/G31.nozzle.diameter
.
.mm.
0.77.
0.77
Gas consumption (**)
Natural.gas.(G20).
m
3
/h.
2.70.
3.17
LPG.(G30/G31).
kg/h.
2.01.
2.37
Burner gas pressure min/max
(G20).
mbar.(kPa).
1.8/11.0.(0.18/1.08).
1.9/11.1.(0.19/1.09)
(G30.-.G31)..
mbar.(kPa). 4.7/27.7.(0.46/2.71).-.4.7/35.7.(0.46/3.50).
4.8/27.7.(0.47/2.71).-.4.8/35.7.(0.47/3.50)
Gas supply pressure
Natural.gas.(G20).
mbar.(kPa).
20.(1.96).
20.(1.96)
Butane.(G30).
mbar.(kPa).
28–30.(2.74-2.94).
28–30.(2.74-2.94)
Propane.(G31).
mbar.(kPa).
37.(3.63).
37.(3.63)
.(*)... Heat.input.of.the.heating.system.measured.using.lower.heating.value.(LHV)
.(**). Gas.consumption.figures.express.the.lowest.calorific.power.of.pure.gas.under.standard.conditions.at.15°C.–.1013.mbar;.this.figure.may.differ.from.the.
actual.figure,.which.is.dependent.on.gas.composition.and.environmental.conditions..
1.3
TECHNICAL FEATURES