NOTE: the inside of the upper door of the
boiler panel has a label with the values
that have to be set for PAR 1 and PAR 2
(fig. 19).
BOILER
PAR 2
Instantaneous boiler with diverter
1
valve microswitch and flow switch
Instantaneous boiler with
diverter valve microswitch,
2
flow switch and solar combining
25/55 - 30/55
3
I-HE 35 MF / E-HE 35 MF
4
Instantaneous boiler with diverter
5
valve and flowmeter
Instantaneous boiler with diverter
6
valve, flowmeter and solar combining
PARAMETERS INSTALLER
EXPANSION CARD
PAR DESCRIPTION
RANGE
UNIT OF
INC/DEC
DEFAULT
MEASUREMENT
UNIT
SETTING
40
Number of expansion boards
0 ... 3
=
1
0
41
Mix valve stroke time
0 ... 199
10 sec.
1
12
42
Priority of D.H.W. over mixed zone
0 = Paralle
=
=
1
1 = Absolute
43
Floor drying
0 = No activated
=
=
0
1 = Curve A
2 = Curve B
3 = Curve A+B
44
Type of solar system
1 ... 7
=
1
1
45
?
t solar collector pump 1
PAR 74 OEM - 1... 50
°C
1
8
46
Solar integration delay
“--”, 0 ... 199
Min.
1
0
47
Tmin solar collector
“--”, -30 ... 0
°C
1
- 10
48
Tmax solar collector
“--”, 80 ... 199
°C
1
120
PARAMETERS RESTORATION
PAR DESCRIPTION
RANGE
UNIT OF
INC/DEC
DEFAULT
MEASUREMENT
UNIT
SETTING
49 * Reset default parameters
-- , 1
=
=
=
(par 01 - par 02 = “-“)
* Should the boiler not be operating correctly, the original default values can be reset by
setting PAR 49 = 1 and the PAR 1 and PAR 2 as specified at point 3.3.1.