54
13.10 Remove/replace system pump
– Shut-off the valves to the system and empty the boiler
– remove the front panel (see "Remove panels" on page 48)
– lift the connector (1) using a screwdriver (2)
1
2
Fig. 79
– unscrew the swivel joints (3) and (4)
– disconnect the pipes (5) and (6)
– unscrew the screw (7)
– unscrew the nut (8) that secures the pump
5
3
7
4
8
6
Fig. 80