29
8.13.2 Chrono-thermostat or Air Thermostat
The electrical connection of the chrono-thermostat or air ther-
mostat has already been described. When fitting the component
in the room where the readings are to be taken, follow the in-
structions provided with the device.
8.13.3 EXAMPLE of use of the command/control de-
vice on some types of heating systems
KEY
M
System delivery
R
System return
CR
Remote control
SE
External temperature sensor
TA
Air thermostat for boiler activation
TZ1÷TZ3 Air thermostat for the zone
VZ1-VZ3 Zone valves
RL1-RL3 Zone relays
P1-P3
Zone pump
TSB
Low temperature safety thermostat
ONE DIRECT ZONE system , external sensor and air thermo-
stat.
R
M
SE
TA
CR
Fig. 34
MULTI ZONE system - with pump, air thermostat and external
sensor.
TA
SE
TZ2
TZ3
TZ1
P3
RL1
SP
RL2
RL3
P2
P1
R
M
Fig. 35
MULTI ZONE system - with zone valve, air thermostat and ex-
ternal sensor.
TA
TZ1
VZ1
VZ2
VZ3
TZ2
TZ3
SE
R
M
Fig. 36
m
CAUTION
Set the parameter "tS 17 = DELAY SYSTEM PUMP AC-
TIVATION to allow the opening of zone valve Vz.
Summary of Contents for 8112265
Page 42: ...42 12 EXPLODED VIEWS Brava Slim HE 20 R i Brava Slim HE 40 R i ...
Page 43: ...43 Brava Slim HE 20 R e Brava Slim HE 40 R e ...
Page 44: ...44 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 45: ...45 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 46: ...46 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 55: ...55 ...