5.9
Circulation pump
The flow-head performance curve available for the heating sys-
tem is shown in the graph below.
RESIDUAL HEAD (mbar)
0
0
800 1000 1200 1400
1600
600
400
200
100
200
300
400
500
600
30 BF
25 BF
FLOW (l/h)
Fig. 13
5.10 Control panel
1
1
2
2
2
2
2
3
Fig. 14
1
KNOBS
t
The heating knob allows the user to set the heating tem-
perature to between 20 and 80°C during normal opera-
tion.
r
The domestic hot water knob allows the user to set the
domestic hot water temperature to between 10 and 60°C
during normal operation.
2
FUNCTIONAL BUTTONS
s
If pressed once or more than once for at least 1 second
during normal operation, this button allows the user to
change the boiler operating mode in a cyclical sequence
(Stand-by – Summer – Winter).
<
This allows the user to scroll through the parameters or
decrease the values.
>
This allows the user to scroll through the parameters or
increase the values.
o
This allows the user to confirm the selected parame-
ter or to modify the value or to "unblock" the appliance
when the alarm for a "block" malfunction is present.
c
Programming connector cover plug.
NOTE:
pressing any one of these buttons for more than 30 sec-
onds generates a fault on the display without preventing boiler
operation. The warning disappears when normal conditions are
restored.
3
DISPLAY
l
“SUMMER”
. This symbol appears when the boiler is oper-
ating in Summer mode or if only the domestic hot water
mode is enabled via the remote control. If the symbols
l
and
n
are flashing, this indicates that the chimney
sweep function is active.
n
“WINTER”
. This symbol appears when the boiler is oper-
ating in Winter mode or if both the domestic hot water
and heating modes are enabled via the remote control.
With the remote control, if no operating modes have
been enabled both symbols
l
and
n
will be off.
R
“RESET REQUIRED”
. This message only appears if there
is a malfunction which must be or may be restored man-
ually.
r
“DOMESTIC HOT WATER”
. This symbol is present during
a request for DHW or when the chimney sweep function
is operating; it flashes during the domestic hot water set
point selection.
t
“HEATING”
. This symbol is present during heating oper-
ation or when the chimney sweep function is operating;
it flashes during the heating set point selection.
f
“BLOCK” DUE TO NO FLAME
.
F
“FLAME PRESENCE"
.
K
“ALARM"
. This indicates that a fault has occurred. The
number specifies the cause which generated the alarm
(see paragraph "Malfunction codes and possible solu-
tions".
H
"MAINTENANCE REQUEST"
. If active, it shows it is time to
perform maintenance on the boiler.