background image

© Baxi Heating UK Ltd 2011

Please keep these instructions in a safe place.

If you move house, please hand them over to the next occupier.

Platinum 2 Combi GA Range

Gas Fired Wall Mounted Condensing

Combination Boiler

i-THINK Set Up Guide,

User’s Operating Instructions &

Important Warranty Information

Summary of Contents for Duo-tec 2 Combi 40 GA

Page 1: ...structions in a safe place If you move house please hand them over to the next occupier Platinum 2 Combi GA Range Gas Fired Wall Mounted Condensing Combination Boiler i THINK Set Up Guide User s Operating Instructions Important Warranty Information ...

Page 2: ...riminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Setting the Time 6 4 0 Setting the Central Heating Times 7 5 0 Mode Selection Temp Adjustment 9 6 0 Resetting the Boiler 13 7 0 Repressurising System 14 8 0 Clearances 15 9 0 Legislation 16 10 0 Care of the Boiler 17 11 0 Fault Finding 18 12 0 Notes 19 13 0 Warranty Service 20 Section Page Conten...

Page 3: ...enu Button Selector Button Turn Push Select The Easy menu button Commonly required functions are available more quickly via the Easy Menu Button To access press the Easy Menu Button and scroll through confirm your selection by pressing the Selector Button Commonly required functions are shown in order below 1 Standby operation The on off switch in the off mode frost protection for the appliance is...

Page 4: ...Flame Indicates burner is on Boiler operating satisfactorily NO YES YES YES Is the E symbol illuminated Yes 157 Boiler flow thermostat Reset Error YES Press the Selector Button to Reset Error Symbol If it does not reset CONTACTYOUR INSTALLER OR SERVICE ENGINEER 266 Fan Fault Error Is the Crossed out Flame and Spanner symbol illuminated or flashing YES Spanner Symbol Boiler Temperature Central Heat...

Page 5: ... 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible CH ON CH OFF bar 0 1 2 3 4 Is the Central Heating System Pressure between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described...

Page 6: ...and date Press the Selector Button and the minute number flashes Turn the Button to the required minute Press the Selector Button Hours minutes 11 30 Set time and date Day month 05 06 Set time and date Turn the Selector Button clockwise until Day month is shown Press the Selector Button and the month number flashes Turn Button to the required month Day month 03 06 Set time and date Press the Selec...

Page 7: ... until the basic display is shown Press the MENU button Time central heating CH3 Operator section Time central heating CH1 Mon Sun Select days Time central heating CH1 Turn the Selector Button clockwise to highlight Time central heating CH1 Press the Selector Button to select Press the Selector Button and the day days regime flashes Turn Button to the required day or days Mon Sun Mon Fri Sat Sun M...

Page 8: ... time will flash Turn the Button to the required time Press Selector Button to select STEP 11 STEP 12 STEP 13 STEP 14 STEP 15 STEP 16 Menu Button Selector Button 04 November 2008 08 50 Tuesday 1 6 bar Easy Menu Button Display Screen 08 00 Mon Sun 1st Time ON Time central heating CH1 Press the Selector Button and the 1st Time ON time will flash Turn the Button to the required time Press Selector Bu...

Page 9: ...programmed times the frost protection reduced temperature period is constantly in the background and will cause the appliance to come on if the room temperature falls below the reduced temperature setpoint 5 default or 5 C during frost protection NOTE Adjustment of the room temperature during these periods will result in a temporary change to the reduced temperature setting until the next On perio...

Page 10: ...e MENU button Turn the Selector Button clockwise to highlight Temps mode hot water Press the Selector Button to select 50 C Hot water temp setpoint Temps mode hot water Turn Selector Button to the required temperature Press the Selector Button to select Temperature setting is now complete 03 June 2009 11 30 Wednesday 1 6 bar Press the MENU button twice to return to normal display screen STEP 1 STE...

Page 11: ...m temperature ie 10 C or temporarily changed by turning the Selector Button between a programmed period and selecting the desired temperature This facility may be used to heat the house outside the programmed periods 4 The reduced temperature setting will revert to the permanently stored value at the beginning of the next programmed period Menu Button Selector Button 04 November 2008 08 50 Tuesday...

Page 12: ...p setpoint are available for change by the user 3 To activate the programme lock a Press the menu button to access Information then scroll and press to choose Operator section scroll to the programme lock option press and scroll from Off to On Confirm by pressing the Selector Button b Accessing programme lines is now still possible but when attempting to alter any parameters the screen will show P...

Page 13: ... reset can only be carried out on the i THINK Controller when on the appliance not as a room sensor 2 To perform a user reset on the appliance i THINK Controller reset appears press the Selector Button twice after a few seconds the error symbol should disappear 3 The error will clear and the appliance will restart if there is a demand for heat as long as the error condition has cleared The user er...

Page 14: ...the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising should the copper pipe be connected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 6 Fully open one of the taps first and then while watching the display on the i THINK or pressure gauge carefully open the second tap 7 When the di...

Page 15: ...50mm For Servicing This is MINIMUM recommended dimension Greater clearance will aid installation and maintenance 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in close proximity to your boiler 9 Avoid skin contact when your boiler is in operation as some surfaces m...

Page 16: ...gulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Body 0086 Ref 86 BL 647 For GB IE only 9 2 Benchmark Commissioning Checklist 1 Please ensure that the ins...

Page 17: ...s been fitted your installer will be able to advise you then to operate correctly and protect your system the gas and electricity must be left on and the appliance set in the central heating mode 3 The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated To prevent seizure the pump will operate for approximately 1 minute if it has...

Page 18: ...as been a flame failure during normal operation 125 is displayed in either of two situations i If between 15 and 30 seconds of the burner lighting the boiler temperature has not changed by 1 C ii If within 10 minutes of the burner lighting the boiler actual temperature twice exceeds the selected temperature by 30 In these instances poor primary circulation is indicated 3 By Resetting when 110 125 ...

Page 19: ...12 0 Notes 19 Baxi Heating UK Ltd 2011 ...

Page 20: ... you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boiler se...

Reviews: