scorpION3 5200969 Rev 4
48
Appendix B
Fault Status Code
Reference Guide
Fault
No.
Message
Possible Causes
Potential Actions
(in order of occurrence)
0
No Faults
N/A
N/A
1
Positive Ion
Output Too Low
Emitters need cleaning.
Emitter housing or emitter
electrode not seated.
HV open circuit.
Pos HV supply is faulty.
Clean emitters.
Check emitter housing & emitter
electrode seating.
Reduce Ion Output setting.
Replace emitter electrodes.
Replace Pos HV supply.
Replace bar.
2
Negative Ion
Output Too Low
Emitters need cleaning.
Emitter housing or emitter
electrode not seated.
HV open circuit.
Neg HV supply is faulty.
Clean emitters.
Check emitter housing & emitter
electrode seating.
Reduce Ion Output setting.
Replace emitter electrodes.
Replace Neg HV supply.
Replace bar.
3
Ion Output Too
Low
Unable to drive Ion Output
from either supply (as
currently set).
Emitters need cleaning.
Emitter housing or emitter
electrode not seated.
HV open circuit.
HV supplies faulty.
Clean emitters.
Check emitter housing & emitter
electrode seating.
Reduce Ion Output setting.
Replace emitter electrodes.
Replace HV supplies.
Replace bar.
Summary of Contents for scorpION3
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...
Page 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...
Page 29: ...scorpION3 5200969 Rev 4 24...
Page 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...
Page 41: ...scorpION3 5200969 Rev 4 36...
Page 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...
Page 49: ...scorpION3 5200969 Rev 4 44...