scorpION3 5200969 Rev 4
10
2.3 Bar Configuration
The scorpION3 bar has two ionization indicators and a window for
receiving and transmitting commands via IR with the MMI,
incorporated into the scorpION3 face label on the front of the bar.
The indicators have multiple functions. The main function of the
indicator is to illuminate when the high voltage power supply is
activated. A green indicator shows that the bar is operating
normally and no faults are present. A red indicator shows that a
fault is present. The indicators will typically briefly flicker rapidly to
show the receipt of IR commands from the MMI.
Each scorpION3 bar can be assigned a unique address. Addresses
are numbers 0-9 and in multi-bar systems, each bar must have a
unique address. Address “0“ designates a master bar, and allows
the master to send messages to other connected bars for pulse
mode synchronization in multiple bar systems. Note that any bar set
to a non-zero address (and set to slave class), will follow the master
bar pulse rate. When no master bar is present, bars with non-zero
addresses will operate independently.
The bar address is used to ensure that operating adjustments are
made only to the desired bar during set-up and calibration. The bar
address is also used to identify operating parameters and alarms
downloaded from a multi-bar system.
Summary of Contents for scorpION3
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...
Page 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...
Page 29: ...scorpION3 5200969 Rev 4 24...
Page 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...
Page 41: ...scorpION3 5200969 Rev 4 36...
Page 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...
Page 49: ...scorpION3 5200969 Rev 4 44...