scorpION3 5200969 Rev 4
6
2.1 Mounting Considerations
Remove the shipping caps (yellow or orange plastic) from each emitter
before placing ionizer in service. The caps protect the ion emitter points
from damage during shipping and must be removed before operating the
bar.
Prior to powering up a single or multi-bar system, the ionizing bar(s)
should be securely mounted using the provided hardware. If the
scorpION3 bar is mounted using hardware not provided with the
unit, it is important to keep any grounded hardware away from the
emitter tips. Introducing a ground near the emitter tips can affect ion
balance and discharge times. The bar should be installed so no
grounded objects are within 300 mm (12”) of the emitter face of the
bar. For applications with no airflow, the bar should be positioned
centered over the work area or the area where static control is
desired. For fan filter type applications where airflow is present,
location relative to the target is less critical, but for best result the
bar should also be centered over the target area.
Summary of Contents for scorpION3
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...
Page 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...
Page 29: ...scorpION3 5200969 Rev 4 24...
Page 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...
Page 41: ...scorpION3 5200969 Rev 4 36...
Page 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...
Page 49: ...scorpION3 5200969 Rev 4 44...