scorpION3 5200969 Rev 4
16
bar. If
save settings local to bar
is not performed and power is
removed from the bar, the changes will be lost.
Change Address
allows changing of the address number for the
bar, 0 thru 9 are possible bar addresses (active bar addresses will
not be offered). The desired address is selected by up/down arrow
button.
Settings
enters a series of menus that use two-way communication
with the bar for adjustment and set-up purposes. The setting mode
may be entered from the Change Address menu. Following are
selections from the Settings menus.
Settings:
Advancing from this menu allows the selection of Settings
or Diagnostics. Following are selections from the
Settings
menus.
Hot Key Tip
: Pressing the
up arrow
and
left arrow
at the same time
will jump the MMI menu to “Settings”.
•
Power
(default: on) may be turned on/off (up/down arrows) for
an individual bar in a system.
•
Output
(default: 50%) may be adjusted for the bar. Using the
up/down arrows adjusts the bar output setting. Output level sets
the ionization output from the ionizer. This value should be set
to the lowest level possible to achieve the desired discharge
time. Higher values of output will result in more ion generation,
which can reduce discharge time, but may result in more
frequent ionizer maintenance. The system will limit maximum
output in cases of long pulse time.
•
Pulse/Steady
(default: pulse) allows selection of Pulse mode
ionization or SSDC (steady state DC) ionization. In pulse mode
the positive and negative ionization will be energized in
alternating sequence. This provides quicker discharge times for
still air but creates a mildly alternating peak offset voltage.
Steady state DC mode maintains constant output for both the
positive and negative ionization. This is more typically used
where there is airflow to carry the ions to the target.
•
Slave/Independent
(default: independent) allows for selection
of the bar as a Slave (non-0 address only) or Independent.
Summary of Contents for scorpION3
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...
Page 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...
Page 29: ...scorpION3 5200969 Rev 4 24...
Page 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...
Page 41: ...scorpION3 5200969 Rev 4 36...
Page 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...
Page 49: ...scorpION3 5200969 Rev 4 44...