scorpION3 5200969 Rev 4
18
likelihood of encountering nuisance fault notification.
•
HV on w/Fault
(default: yes) allows disabling of the ionizer by
turning off the high voltage power supplies if a fault state is
entered.
•
Fault Contacts
(default: N.O.) allows setting of the Fault
Output opto-isolated transistor as N.O. (normally open) or N.C.
(normally closed).
•
Save settings local to bar?
(default: no) Saves the changes
made to the operating parameters for the bar into the memory of
the bar. “Y” must be selected with the down arrow, then ENTER
pressed to save settings. The green indicator lights on the bar
and MMI will flicker to confirm saving of settings. This operation
must be performed to ensure the changes will not be lost.
Hot Key Tip
: Pressing the
up arrow
and
right arrow
at the same time
will jump the MMI menu to “Save settings local to bar”.
•
Save as preset?
(default: no) This is the option to saving the
changes local to bar. It allows selection of the desired preset
number (P1 through P14) and saving the parameters under this
preset for later downloading into a bar.
•
Upload Settings to Bar?
(default: no) Uploads the active
preset to a bar. The up/down arrows select the target bar
address. Pressing ENTER uploads the preset to the bar (but
does not save the settings local to bar). In IR mode the MMI will
prompt the user to point the MMI at the bar and press ENTER.
Diagnostic
enters a series of menus that use two-way
communication with the bar for diagnostic purposes. The
diagnostic mode may be entered from the Change Address menu.
Following are selections from the Diagnostic menus.
•
Feedback
is data transmitted back from the bar to the MMI:
Hot Key Tip
: Pressing the
down arrow
and
left arrow
at the same
time will jump the MMI menu to the Feedback screen.
•
PRG
Metered feedback ‘Program’ is the input value to the ion
regulating circuitry as established by the microprocessor.
There is a ‘Program’ value for the positive and negative high
Summary of Contents for scorpION3
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...
Page 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...
Page 29: ...scorpION3 5200969 Rev 4 24...
Page 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...
Page 41: ...scorpION3 5200969 Rev 4 36...
Page 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...
Page 49: ...scorpION3 5200969 Rev 4 44...