3.5 On- and Off-times (Pulsed DC Mode
Only)
About On- and Off-times
If the decay time is too slow and the voltage swings are less than
100V, increase both the positive and negative ontimes in 0.1
second increments, checking the positive and negative decay times
between each adjustment. When changes no longer positively
improve performance, set the ontime and offtime at the last
beneficial setting.
Adjusting On- and Off-times
.
It is important to set positive and negative on or offtimes in
coordination with environmental readings you get during a balance
adjustment. See the Balance Adjustment section in this chapter.
1. Access the TFS Menu by holding down any button while turning
on the remote control. A password prompt will appear.
2. Enter the following password: Esc, Down, Up, Select, Select,
Select, Select.
3. Use the Up or Down button to reach the desired PosOn, PosOff,
NegOn, or NegOff item. Press Select.
4. Use the Up or Down button to change the timing parameter.
Press Esc to exit from the change action.
Summary of Contents for AeroBar 5225S
Page 5: ...19 5225S M 01 Rev 2 1 1 Description 1 1 Overview 1 2 Remote Control 1 3 Power Requirements...
Page 12: ...19 5225S M 01 Rev 2 8...
Page 42: ...19 5225S M 01 Rev 2 38...
Page 51: ...19 5225S M 01 Rev 2 47...
Page 57: ...19 5225S M 01 Rev 2 53 5 3 Dimensional Drawings Standard Lengths...
Page 58: ...19 5225S M 01 Rev 2 54 300 mm EFEM Application Lengths...
Page 59: ...19 5225S M 01 Rev 2 55...
Page 61: ...19 5225S M 01 Rev 2 57...
Page 62: ...19 5225S M 01 Rev 2 58 Notes...