background image

www.silverlinetools.com

7

228541

Digital Clamp Meter

Terms & Conditions

Silverline Tools Guarantee

This Silverline product comes with a 3 year 

guarantee

Register this product at www.silverlinetools.com within 30 days of 
purchase in order to qualify for the 3 year guarantee. Guarantee period 
begins according to the date of purchase on your sales receipt.

Registering your purchase 

Registration is made at silverlinetools.com by selecting the Guarantee 
Registration button.  You will need to enter:-
•  Your personal details
•  Details of the product and purchase information 
Once this information is entered your guarantee certificate will be created 
in PDF format for you to print out and keep with your purchase.  

Guarantee period becomes effective from the date of retail purchase as 
detailed on your sales receipt.

PLEASE KEEP YOUR SALES RECEIPT

If this product develops a fault within 30 days of purchase, return it to the 
stockist where it was purchased, with your receipt, stating details of the 
fault. You will receive a replacement or refund.
If this product develops a fault after the 30 day period, return it to:

Silverline Tools Service Centre 

PO Box 2988 

Yeovil 

BA21 1WU, UK

The guarantee claim must be submitted during the guarantee period.
You must provide the original sales receipt indicating the purchase date, 
your name, address and place of purchase before any work can be  
carried out.
You must provide precise details of the fault requiring correction.
Claims made within the guarantee period will be verified by Silverline Tools 
to establish if the deficiencies are related to material or manufacturing of 
the product.
Carriage will not be refunded. Items for return must be in a suitably clean 
and safe state for repair, and should be packaged carefully to prevent 
damage or injury during transportation. We may reject unsuitable or  
unsafe deliveries.
All work will be carried out by Silverline Tools or its authorized  
repair agents.
The repair or replacement of the product will not extend the period  
of guarantee
Defects recognised by us as being covered by the guarantee shall be 
corrected by means of repair of the tool, free of charge (excluding carriage 
charges) or by replacement with a tool in perfect working order.
Retained tools, or parts, for which a replacement has been issued, will 
become the property of Silverline Tools. 

The repair or replacement of your product under guarantee provides 
benefits which are additional to and do not affect your statutory rights as 
a consumer.

What is covered:

The repair of the product, if it can be verified to the satisfaction of Silverline 
Tools that the deficiencies were due to faulty materials or workmanship 
within the guarantee period.
If any part is no longer available or out of manufacture, Silverline Tools will 
replace it with a functional replacement part.
Use of this product in the EU.

What is not covered:

Silverline Tools does not guarantee repairs required as a result of:
Normal wear and tear caused by use in accordance with the operating 
instructions eg blades, brushes, belts, bulbs, batteries etc.
The replacement of any provided accessories drill bits, blades, sanding 
sheets, cutting discs and other related items.
Accidental damage, faults caused by negligent use or care, misuse, 
neglect, careless operation or handling of the product.
Use of the product for anything other than normal domestic purposes.
Change or modification of the product in any way.
Use of parts and accessories which are not genuine Silverline Tools 
components.
Faulty installation (except installed by Silverline Tools).
Repairs or alterations carried out by parties other than Silverline Tools or its 
authorized repair agents.
Claims other than the right to correction of faults on the tool named in 
these guarantee conditions are not covered by the guarantee.

EC Declaration of Conformity

The undersigned: 

Mr Darrell Morris

as authorised by: 

Silverline Tools

Declares that the

Name/ model: 

Digital Clamp Meter 

Type/ serial no: 

228541

Conforms to the following Directives:

•  EMC Directive 2004/108/EC 

•  Low voltage directive 2006/95/EC

•  ROHS Directive 2002/95/EC

•  EN61010-2:2010; EN61010-031:2002+A1:2008 

•  EN61326-1:2006 

The technical documentation is kept by: 

Silverline Tools

Notified body: 

VOP

Place of declaration: 

Vyskov, Czechoslovakia

Date: 

 07/09/11

Signed by:

Director

Name and address of Manufacturer or Authorised representative:

Silverline Tools, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,  

BA22 8HZ United Kingdom

228541_Z1MANPRO1.indd   7

25/10/2011   09:54

Summary of Contents for 228541

Page 1: ...ahre Garantie Registrieren Sie sich innerhalb von 30 Tagen online Es gelten die allgemeinen Gesch ftsbedingungen 3 a os de garant a Reg strese online dentro de 30 d as Se aplican los t rminos y condic...

Page 2: ...com Digital Clamp Meter AC DC Digital Clamp Meter Pince amp rem trique num rique Digitales Zangenmessger t Pinza amperim trica digital Pinza amperometrica digitale Digitale amp retang 228541_Z1MANPRO...

Page 3: ...2 9 10 8 7 1 2 4 5 3 6 228541_Z1MANPRO1 indd 2 25 10 2011 09 54...

Page 4: ...www silverlinetools com 3 English 4 Fran ais 8 Deutsch 12 Espa ol 16 Italiano 20 Nederlands 24 Digital Clamp Meter AC DC 228541_Z1MANPRO1 indd 3 25 10 2011 09 54...

Page 5: ...all ranges DC Voltage Range Resolution Accuracy 50Hz 500Hz 600V Overload Protection Input Impendance 1V 1 of reading 2 digits 600V DC peak AC on all ranges 9M Environment Temperature Normal Operation...

Page 6: ...not force or attempt to use a tool for a purpose for which it was not designed This tool is not intended for industrial use Wear suitable clothing and footwear Do not wear loose fitting clothing neck...

Page 7: ...e clamped at the same time AC Voltage Measurement 1 Set Rotary Switch 4 to the V 600 position 2 Insert the red lead into the V Input Connector 9 and the black lead to the COM Input Connector 8 3 Conne...

Page 8: ...excluding carriage charges or by replacement with a tool in perfect working order Retained tools or parts for which a replacement has been issued will become the property of Silverline Tools The repa...

Page 9: ...V CA CC pour toutes plages Tension courant continu Plage R solution Pr cision 50 Hz 500 Hz 600 V Protection surcharge Imp dance entr e 1 V 1 2 du relev 2 600 V CC max CA pour toutes les plages 9 M Ess...

Page 10: ...ts et animaux Maintenez une distance de s curit entre les enfants ou les animaux et votre zone de travail Rangez les outils dans un lieu s r ferm cl hors de port e des enfants Utilisation correcte de...

Page 11: ...cuit tester et effectuez le relev Mesure de tension continue 1 Placez le commutateur rotatif 4 sur la position V 600 2 Ins rez le fil rouge dans le connecteur d entr e V 9 et le fil noir dans le conne...

Page 12: ...de port ne seront pas rembours s Les articles retourn s doivent tre convenablement propres et s rs pour tre r par s et devraient tre emball s soigneusement pour viter tout dommage ou toute blessure p...

Page 13: ...nkt und entsprechendem Vorzeichen 9 V Batterie Bei Alkalibatterien typischerweise bis zu 200 Stunden Bei Zinkbatterien typischerweise bis zu 150 Stunden Anzeige zeigt LO BAT wenn ca 20 der Batterieleb...

Page 14: ...kt oder im Nacken zusammengebunden werden Gleichgewicht halten Vermeiden Sie eine unnat rliche K rperhaltung sorgen Sie f r einen sicheren Stand und halten Sie stets das Gleichgewicht Verwenden Sie ke...

Page 15: ...e den Messwert ab Messung von Gleichspannung 1 Stellen Sie den Drehschalter 4 auf die Position V 600 2 F hren Sie das rote Kabel in den V Eingang 9 und das schwarze Kabel in den COM Eingang 8 ein 3 Ve...

Page 16: ...terial oder Herstellung des Produkts bedingt ist Transportkosten werden nicht erstattet Eingereichte Produkte sollten sich in einem zur Reparatur geeigneten sauberen und sicheren Zustand befinden und...

Page 17: ...los rangos Rango Resoluci n Precisi n 50 Hz 500 Hz 600 V Impedancia de entrada Protecci n de sobrecarga 1 V 1 de lectura 2 9 M 600 V CC pico CA en todos los rangos Tensi n de CC Como parte de nuestro...

Page 18: ...o con puntera protectora El pelo largo se debe cubrir o anudarse en coleta atr s Mantenga su equilibrio Evite posturas arriesgadas Trabaje sobre una base firme y mantenga el equilibrio en todo momento...

Page 19: ...uito a probar y tome la lectura Medici n de tensi n de CC 1 Ponga el Selector giratorio de funci n 4 en la posici n V 600 2 Introduzca el cable rojo en el conector de entrada V 9 y el cable negro en e...

Page 20: ...ilverline Tools con el fin de establecer si las deficiencias son consecuencia de los materiales o de la mano de obra del producto Los gastos de transporte no son reembolsables Todo producto a devolver...

Page 21: ...Tenuta dati Peso Corrente AC Voltaggio AC Voltaggio DC Resistenza Test di continuit 18 C 28 C 0 C 50 C 20 C 60 C con batteria tolta e 80 UR Max 80 Integrazione tecnica pendenza doppia 3 letture sec Au...

Page 22: ...to Evitare di utilizzare qualunque tipo di attrezzatura priva delle relative protezioni Se le protezioni presentano segni di danneggiamento procedere alla loro sostituzione prima dell utilizzo del pro...

Page 23: ...2 Inserire il cavo rosso nel connettore input V 9 e quello nero nel connettore input COM 8 3 Collegare le sonde al circuito testato e rilevare la lettura Misura del voltaggio DC 1 Mettere l interrutto...

Page 24: ...ato sono coperti dalla garanzia Silverline Tools provveder a riparare l utensile gratuitamente esclusi i costi di spedizione o a propria discrezione a sostituirlo con un nuovo utensile Gli utensili o...

Page 25: ...dubbele helling 3 uitlezingen sec Automatisch min aangegeven plus verondersteld wanneer niet aangegeven Alle cijfers verwijderd behalve het meest significante cijfer de komma en minteken indien aanwez...

Page 26: ...bedekt of opgebonden Houd uw evenwicht Reik niet te ver zorg dat u altijd stevig staat en gebruik het gereedschap niet als u op een onstabiele ondergrond staat Toebehoren Het gebruik van hulpstukken o...

Page 27: ...ertje in de COM ingang 8 3 Sluit de sondes op het te testen circuit aan en voer een meting uit Gelijkspanning meten 1 Zet de draaischakelaar 4 op V 600 2 Stop het rode snoertje in de V ingang 9 en het...

Page 28: ...endkosten worden niet vergoed De geretourneerde items moeten voor de reparatie in een redelijk schone en veilige staat verkeren en moeten zorgvuldig worden verpakt om schade en letsel tijdens het verv...

Reviews: