background image

4

GB

Description of Symbols

The rating plate on your tool may show symbols. These represent important 
information about the product or instructions on its use.

Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection

Wear hand protection

Read instruction manual

Conforms to relevant legislation and safety standards

Environmental Protection 

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. Check with 
your local authority or retailer for recycling advice

 

Specification

 

  

The following specifications assume a 1-year calibration cycle and 
an operating temperature of 18°C to 28°C (64°F to 82°F) at relative 
humidity up to 80% unless otherwise noted.

AC Current

(Average sensing, calibrated to rms of sine wave)

Range

Resolution

Accuracy (50Hz - 60Hz)

200A

1000A

Overload Protection:

Jaw Opening:

100mA

1A

±(2.5% of reading ±10 digits)

±(2% of reading ±5 digits

for 800A and below

± (3% of reading ±5 digits)

for other current

1000A within 60 seconds

2" (5cm)

AC Voltage

(Average sensing, calibrated to rms of sine wave)

Range

Resolution

Accuracy (50Hz - 500Hz)

600V

Input Impendance:

Overload Protection:

1V

±(1.2% of reading ±5 digits)

9M

Ω

600V AC/DC on all ranges

DC Voltage

Range

Resolution

Accuracy (50Hz - 500Hz)

600V

Overload Protection: 

Input Impendance:

1V

±(1% of reading ±2 digits)

600V DC/peak AC on all 

ranges

9M

Ω

 

Environment

Temperature:

Normal Operation: 

Usable Condition:

Storage:

Relative Humidity:

Measurement Method:

Reading Rate:

Polarity:

Overload Indication:

Power Requirements:

Battery Life:

Battery Indication:

Display:

Data Hold:

Weight:

AC Current:

AC Voltage:

DC Voltage:

Resistance:

Continuity Test:

18

˚

C-28

˚

C

0

˚

C-50

˚

C

-20

˚

C-+60

˚

C

battery removed and<80% RH

Max. 80%

Dual slope integration technical

3 reading/sce

Automatic, indicated minus, 

assumed plus

Blanking of all digits, except 

MSD,decimal point and sign 

appropiate

9V Battery

Up to 200 hours typical with 

Alkaline

Up to150 hours typical with Zinc

Display indicates LO BAT when 

approximately 20% of battery 

life remains

LCD 3

1

2

 digit (1999 count) 

0.5" high

All function and ranges with this 

feature

Approx 11 ounces (310 grams)

0.1A to 1000A

1V to 600V

1V to 600V

200

Ω

 to 2000M

Ω

30+ 20

Ω

 with audio tone

(64

˚

F-82

˚

F)

(32

˚

F-122

˚

F)

(-30

˚

F-140F)

Resistance

Range

Resolution

Accuracy (50Hz - 500Hz)

200

Ω

20K

Ω

 

Overload Protection:

0.1

Ω

10

Ω

±(1% of reading ±3 digits)

±(1% of reading ±1 digits)

500V DC/rms AC on all ranges

Continuity Test

Range:

Buzzer Sound: 

Overload Protection:

200

Ω

30+ 20

Ω

500V DC/rms AC

As part of our ongoing product development, specifications of 

Silverline products may alter without notice.

228541_Z1MANPRO1.indd   4

25/10/2011   09:54

Summary of Contents for 228541

Page 1: ...ahre Garantie Registrieren Sie sich innerhalb von 30 Tagen online Es gelten die allgemeinen Gesch ftsbedingungen 3 a os de garant a Reg strese online dentro de 30 d as Se aplican los t rminos y condic...

Page 2: ...com Digital Clamp Meter AC DC Digital Clamp Meter Pince amp rem trique num rique Digitales Zangenmessger t Pinza amperim trica digital Pinza amperometrica digitale Digitale amp retang 228541_Z1MANPRO...

Page 3: ...2 9 10 8 7 1 2 4 5 3 6 228541_Z1MANPRO1 indd 2 25 10 2011 09 54...

Page 4: ...www silverlinetools com 3 English 4 Fran ais 8 Deutsch 12 Espa ol 16 Italiano 20 Nederlands 24 Digital Clamp Meter AC DC 228541_Z1MANPRO1 indd 3 25 10 2011 09 54...

Page 5: ...all ranges DC Voltage Range Resolution Accuracy 50Hz 500Hz 600V Overload Protection Input Impendance 1V 1 of reading 2 digits 600V DC peak AC on all ranges 9M Environment Temperature Normal Operation...

Page 6: ...not force or attempt to use a tool for a purpose for which it was not designed This tool is not intended for industrial use Wear suitable clothing and footwear Do not wear loose fitting clothing neck...

Page 7: ...e clamped at the same time AC Voltage Measurement 1 Set Rotary Switch 4 to the V 600 position 2 Insert the red lead into the V Input Connector 9 and the black lead to the COM Input Connector 8 3 Conne...

Page 8: ...excluding carriage charges or by replacement with a tool in perfect working order Retained tools or parts for which a replacement has been issued will become the property of Silverline Tools The repa...

Page 9: ...V CA CC pour toutes plages Tension courant continu Plage R solution Pr cision 50 Hz 500 Hz 600 V Protection surcharge Imp dance entr e 1 V 1 2 du relev 2 600 V CC max CA pour toutes les plages 9 M Ess...

Page 10: ...ts et animaux Maintenez une distance de s curit entre les enfants ou les animaux et votre zone de travail Rangez les outils dans un lieu s r ferm cl hors de port e des enfants Utilisation correcte de...

Page 11: ...cuit tester et effectuez le relev Mesure de tension continue 1 Placez le commutateur rotatif 4 sur la position V 600 2 Ins rez le fil rouge dans le connecteur d entr e V 9 et le fil noir dans le conne...

Page 12: ...de port ne seront pas rembours s Les articles retourn s doivent tre convenablement propres et s rs pour tre r par s et devraient tre emball s soigneusement pour viter tout dommage ou toute blessure p...

Page 13: ...nkt und entsprechendem Vorzeichen 9 V Batterie Bei Alkalibatterien typischerweise bis zu 200 Stunden Bei Zinkbatterien typischerweise bis zu 150 Stunden Anzeige zeigt LO BAT wenn ca 20 der Batterieleb...

Page 14: ...kt oder im Nacken zusammengebunden werden Gleichgewicht halten Vermeiden Sie eine unnat rliche K rperhaltung sorgen Sie f r einen sicheren Stand und halten Sie stets das Gleichgewicht Verwenden Sie ke...

Page 15: ...e den Messwert ab Messung von Gleichspannung 1 Stellen Sie den Drehschalter 4 auf die Position V 600 2 F hren Sie das rote Kabel in den V Eingang 9 und das schwarze Kabel in den COM Eingang 8 ein 3 Ve...

Page 16: ...terial oder Herstellung des Produkts bedingt ist Transportkosten werden nicht erstattet Eingereichte Produkte sollten sich in einem zur Reparatur geeigneten sauberen und sicheren Zustand befinden und...

Page 17: ...los rangos Rango Resoluci n Precisi n 50 Hz 500 Hz 600 V Impedancia de entrada Protecci n de sobrecarga 1 V 1 de lectura 2 9 M 600 V CC pico CA en todos los rangos Tensi n de CC Como parte de nuestro...

Page 18: ...o con puntera protectora El pelo largo se debe cubrir o anudarse en coleta atr s Mantenga su equilibrio Evite posturas arriesgadas Trabaje sobre una base firme y mantenga el equilibrio en todo momento...

Page 19: ...uito a probar y tome la lectura Medici n de tensi n de CC 1 Ponga el Selector giratorio de funci n 4 en la posici n V 600 2 Introduzca el cable rojo en el conector de entrada V 9 y el cable negro en e...

Page 20: ...ilverline Tools con el fin de establecer si las deficiencias son consecuencia de los materiales o de la mano de obra del producto Los gastos de transporte no son reembolsables Todo producto a devolver...

Page 21: ...Tenuta dati Peso Corrente AC Voltaggio AC Voltaggio DC Resistenza Test di continuit 18 C 28 C 0 C 50 C 20 C 60 C con batteria tolta e 80 UR Max 80 Integrazione tecnica pendenza doppia 3 letture sec Au...

Page 22: ...to Evitare di utilizzare qualunque tipo di attrezzatura priva delle relative protezioni Se le protezioni presentano segni di danneggiamento procedere alla loro sostituzione prima dell utilizzo del pro...

Page 23: ...2 Inserire il cavo rosso nel connettore input V 9 e quello nero nel connettore input COM 8 3 Collegare le sonde al circuito testato e rilevare la lettura Misura del voltaggio DC 1 Mettere l interrutto...

Page 24: ...ato sono coperti dalla garanzia Silverline Tools provveder a riparare l utensile gratuitamente esclusi i costi di spedizione o a propria discrezione a sostituirlo con un nuovo utensile Gli utensili o...

Page 25: ...dubbele helling 3 uitlezingen sec Automatisch min aangegeven plus verondersteld wanneer niet aangegeven Alle cijfers verwijderd behalve het meest significante cijfer de komma en minteken indien aanwez...

Page 26: ...bedekt of opgebonden Houd uw evenwicht Reik niet te ver zorg dat u altijd stevig staat en gebruik het gereedschap niet als u op een onstabiele ondergrond staat Toebehoren Het gebruik van hulpstukken o...

Page 27: ...ertje in de COM ingang 8 3 Sluit de sondes op het te testen circuit aan en voer een meting uit Gelijkspanning meten 1 Zet de draaischakelaar 4 op V 600 2 Stop het rode snoertje in de V ingang 9 en het...

Page 28: ...endkosten worden niet vergoed De geretourneerde items moeten voor de reparatie in een redelijk schone en veilige staat verkeren en moeten zorgvuldig worden verpakt om schade en letsel tijdens het verv...

Reviews: