AN332
Rev. 0.8
213
Command 0x13. GET_PROPERTY
Gets a property as shown in Table 22, “Stereo Audio ADC Mode Property Summary,” on page 206. The CTS bit
(and optional interrupt) is set when it is safe to send the next command. This command may only be sent when in
powerup mode.
Available in: All
Command arguments: Three
Response bytes: Three
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
1
1
ARG1
0
0
0
0
0
0
0
0
ARG2
PROP
H
[7:0]
ARG3
PROP
L
[7:0]
ARG
Bit
Name
Function
1
7:0
Reserved
Always write to 0.
2
7:0
PROP
H
[7:0]
Property High Byte.
This byte in combination with PROP
L
is used to specify the property to get.
3
7:0
PROP
L
[7:0]
Property Low Byte.
This byte in combination with PROP
H
is used to specify the property to get.
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
X
ASQINT
X
RESP1
0
0
0
0
0
0
0
0
RESP2
PROPD
H
[7:0]
RESP3
PROPD
L
[7:0]
RESP
Bit
Name
Function
1
7:0
Reserved
Always returns 0.
2
7:0
PROPD
H
[7:0]
Property Value High Byte.
This byte in combination with PROPD
L
represents the requested property
value.
3
7:0
PROPD
L
[7:0]
Property Value High Byte.
This byte in combination with PROPD
H
represents the requested property
value.