AN332
Rev. 0.8
211
Command 0x11. POWER
_
DOWN
Moves the device from powerup to powerdown mode. The CTS bit (and optional interrupt) is set when it is safe to
send the next command. This command may only be sent when in powerup mode. Note that only the POWER_UP
command is accepted in powerdown mode.
If the system controller writes a command other than POWER_UP
when in powerdown mode, the device does not respond. The device will only respond when a POWER_UP
command is written. GPO pins are powered down and not active during this state. For optimal power down
current, GPO2 must be either internally driven low through GPIO_CTL command or externally driven low.
Note:
The following describes the state of all the pins when in powerdown mode:
GPIO1, GPIO2, and GPIO3 = 0
DOUT, DFS, RIN, LIN = HiZ
Available in: All
Command arguments: None
Response bytes: None
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
0
1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
X
X
X