A N 3 3 2
116
Rev. 0.8
Property 0x1903. FM_NB_IIR_FILTER
Sets the bandwidth of the noise floor estimator. The CTS bit (and optional interrupt) is set when it is safe to send
the next command. This property may only be set or read when in powerup mode. The default is 300 (465 Hz).
Bandwidth (Hz) = NB_IIR_FILTER[15:0] x 1.55
Available in: Si4742/43/44/45
Default: 0x012C
Range: 300–1600
Note:
Was property 0x4109 in FW2.B.
Property 0x1904. FM_NB_DELAY
Delay in micro-seconds before applying impulse blanking to the original samples. The CTS bit (and optional
interrupt) is set when it is safe to send the next command. This property may only be set or read when in powerup
mode. The default is 170 µs.
Available in: Si4742/43/44/45
Default: 0x00AA
Range: 125–219
Note:
Was property 0x410A in FW2.B.
Bit
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
NB_IIR_FILTER [15:0]
Bit
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
NB_DELAY [15:0]