28
007-5653-001
4: Chassis Setup and Maintenance
The Intelligent Battery Backup Unit (IBBU) protects the integrity of the cached data on the
megaRAID controller for up to 72 hours in the event of a complete AC power failure or a brief
power outage.
Note:
Your operating system must have RAID support to enable the hot-plug capability of the
drives.
Important:
Regardless of how many hard drives are installed, all drive carriers must remain in
the drive bays to maintain proper airflow.
Caution:
Use caution when working around the SATA backplane. Do not touch the backplane
with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes,
which aid in proper airflow.
Removing the Hard Drive Carriers from the Chassis
To remove the hard drive carriers, perform the following steps (see
Figure 4-1
):
1.
Press the release button on the drive carrier. This extends the drive carrier handle.
2.
Use the handle to pull the drive carrier out of the chassis.
!
!