Factory Defaults
77
At the right on the front panel of the Fibre Channel Hub is an RJ11 port for
communicating with the system console. Table A-3 shows specifications for this
connector.
The front panel also has a standard 10-Base-T Ethernet port, above the serial port.
Factory Defaults
The factory defaults are the recommended settings. Table A-4 summarizes factory
defaults.
Table A-3
Console (Serial) RJ11 Connector Specifications
Pin
Signal
Description
1
DTR
Data Terminal Ready
2
TXD
Transmit Data
3
GND
Ground
4
RXC
Receive Data Common
5
RXD
Receive Data
6
DSR
Data Set Ready
Table A-4
Fibre Channel Hub Factory Defaults
Specification
Value
Passwords
Administrator password: system
Remote login password: access
Hub manager name
DHMxxxxxx, where xxxxxx is the last six digits of
the MAC address without the dashes
Console port configuration
9600 bps, 8 data, 1 stop, no parity, Xon/Xoff
Telnet port number
23
Autobypass ports on error burst
Bypass any port for errors in 7 out of any 10 sample
intervals; reinsert if no errors occur in 10 intervals
Forced port bypass