AUX

ARM/DIS

AUX

ARM/DIS

AUX

ARM/DIS

AUX

PANIC

LOCK

UNLOCK

#

Button 

Function

Confirmation = Change Function

1

ARM/DIS or LOCK

Chirp Status Indication and Single/

1 Beep =

Chirp Status Indication “On”

Dual Unlock Outputs

2 Beeps = Chirp Status Indication “ Off”

2A

AUX (2-Button) or

Mode “P”

1 Beep =

Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On”

TRUNK (3-Button) or

Both will arm 10 seconds after last door is closed or rearm 10 seconds after remote disarm.

UNLOCK

2 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On”

Both will arm 20 seconds after last door is closed or rearm 20 seconds after remote disarm.

3 Beeps = Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On”

Both will arm 45 seconds after last door is closed or rearm 60 seconds after remote disarm.

4 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On”

The starter will disable 70 seconds after last door is closed.

5 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “Off”

2B

AUX (2-Button) or

Mode “S”

1 Beep =

Automatic Arming of Alarm “On”, Automatic Arming of Starter Disable “On”

UNLOCK

Both will arm 30 seconds after last door is closed.

2 Beeps = Automatic Arming of Alarm “Off”, Automatic Arming of Starter Disable “On”

The starter will disable 70 seconds after last door is closed.

3

Red Button on  

Remote Panic from Factory Keyless

1 Beep =

Panic “On”

5910P Only

Keyless Transmitter

2 Beeps = Panic “Off”

4

ARM/DIS (2-

Safety Illumination Sentinel System

3 Beeps = Safety Illumination Sentinel System “On”

AUX (2 Button) or

4 Beeps = Safety Illumination Sentinel System “Off”

LOCK + UNLOCK

AUX

UNLOCK

LOCK

PANIC

LOCK

UNLOCK

AUX

Note: The auto arm door locking feature has
a default setting of "off" in customer mode.
To turn on or off the auto arm door locking
feature in customer mode, repeat the steps
for the "Blue" button and hold the transmitter
button down for more than 3 seconds to get
a second confirmation chirp. For example: (1
chirp = 10 sec auto arm on, auto door lock
off.) (1 chirp + 1 chirp = 10 sec auto arm on,
auto door lock on.)

REMOTE FEATURE PROGRAMMING USING THE CONSUMER’S TRANSMITTER

Consumer Remote Feature Programming 

(7921P, 7920P, 7919P Rev. C)

FEATURE PROGRAMMING USING THE CONTROL MODULE’S DIP SWITCHES

The Silencer

®

model 7921P control module offers 3

programmable features. Follow the instructions enclosed to
program these features using the Dip switches in the control
module.

O

N

1

2         3

O

N

1

2         3

#2 Dip
Switch in the
“Off”
Position

#2 Dip
Switch in the
“On”
Position

Difference Between if a Dip Switch in Off or On

Dip Switch #1: Ignition Key Controlled Lock/Unlock (Door lock control function

must be connected and the door lock output feature must be “on” in the dealer
mode) 

Note: This feature can be programmed using the #1 Dip switch in both the
dealer and consumer modes.

Place Dip switch #1 to the “On” position to activate this feature.

Place Dip switch #1 in the “Off” position to deactivate this feature. 

Dip Switch #2: Current Sensing 

Note: This feature can be programmed using the #2 Dip switch in both the
dealer and consumer modes.

Place Dip switch #2 to the “On” position to have the current sensing feature on.

Place Dip switch #2 in the “Off” position to have the current sensing feature off.

Dip Switch #3: Door Entry Delay (Applies to 7921P only)

Note: This feature can be pre-programmed in dealer mode using the #3 dip
switch. The feature will not be functional in the dealer mode but will become
functional when the unit is converted to customer mode. 

Place Dip switch #3 in the "on" position. During customer mode operation, the
(+) or (-) door input trigger wires will have a 20 second entry delay. This is
primarily used for Ford vehicles that have keyless entry and use a door
mounted keypad. 

Place Dip switch #3 in the "off" position (Factory default) and the 20 second
door entry delay will be off (Instant Activation).

Back View of Housing

Dip Switches

ON

Proposed

© 2005 Copyright Magnadyne Corp.

1111 West Victoria Street 
Compton, CA 90220

www.magnadyne.com

 

Summary of Contents for 7921P

Page 1: ...he factory installed power door locking system to arm and disarm the 7921P security system Step 3 5 Pin Power Harness Installation The power harness contains 3 wires and two vacant sockets this power harness does not come packaged with the alarm module but in 5901H1 5901H2 5901H3 harness kits or custom starter disable power interface harnesses Packaged with the 10 pin main harness are two loose wi...

Page 2: ...ronic Siren Blue White Wire Signal Output to Disarm Factory Alarm Gray Wire Horn Pulsed Output Starter Disable Socket Driver s Door Lock Unlock Factory Keyless Module Typical Left Door Lock Unlock Switch Lock Unlock Right Door Lock Unlock Switch Left Door Jamb Right Door Jamb Lock Unlock Lock Unlock Right Front Pass Door Left Rear Pass Door Lock Unlock Right Rear Pass Door Lock Unlock B C A C A C ...

Page 3: ...Arming of Alarm On Automatic Arming of Starter Disable On Both will arm 45 seconds after last door is closed 2 Beeps Automatic Arming of Alarm Off Automatic Arming of Starter Disable On The starter will disable 70 seconds after last door is closed 3 Red Remote Panic from Factory Keyless 1 Beep Panic On Entry Transmitter 2 Beeps Panic Off 4 Black Blue Safety Illumination Sentinel System 3 Beeps Saf...

Page 4: ...own for more than 3 seconds to get a second confirmation chirp For example 1 chirp 10 sec auto arm on auto door lock off 1 chirp 1 chirp 10 sec auto arm on auto door lock on REMOTE FEATURE PROGRAMMING USING THE CONSUMER S TRANSMITTER Consumer Remote Feature Programming 7921P 7920P 7919P Rev C FEATURE PROGRAMMING USING THE CONTROL MODULE S DIP SWITCHES The Silencer model 7921P control module offers...

Page 5: ... Auto Arm is ON Pre Programmed Consumer Mode Auto Arm 2 Beeps Automatic Arm Door Locking OFF Consumer Auto Arm is ON 3 Beeps Automatic Arm Door Locking On Consumer Auto Arm is OFF 4 Beeps Automatic Arm Door Locking OFF Consumer Auto Arm is OFF 3 Red Chirp Status Indicator On Off 1 Beep On 2 Beeps Off 4 Black Blue Selects P or S Mode Operation 4 Beeps Mode P See 2A Consumer Programming Automatic Ar...

Page 6: ...tton Consumer Switch Black Button Push the Valet Switch 3 Times for Red Button 6 Times for Black Button Represents 3 Times On Off A Long horn chirp indicates the unit is in code learning mode B LED comes on indicating the unit is in code learning mode W A K I N G U P A U N I T F R O M T H E S L E E P M O D E ON OFF Momentary Switch Push On Off Toggle Switch Push On then push it again for off S t e...

Page 7: ...e White Sleep Key into the Receptacle In the event the customer declines to purchase the Silencer security system and the system is not going to be removed from the vehicle it must be put into Sleep mode to prevent automatic arming The white sleep key can also be used to delete a dealer code and to reset the security system to it s original state as it was received from the factory Note The system...

Page 8: ...t Switch S t e p 2 Dealer Switch Red Button Consumer Switch Black Button Insert the Orange Delete Code Key into the Receptacle Upon the customer purchasing the 6905P or 6909P it will arm disarm from the factory keyless remotes He she also has the option of purchasing a customer key pack 5900PKP to disarm the security system In the event the customer declines to purchase the customer Key Pack 5900P...

Page 9: ...itch S t e p 1 Dealer Switch Red Button Consumer Switch Black Button Push the Valet Switch 3 Times for Red Button 6 Times for Black Button Represents 3 Times On Off A Long horn chirp indicates the unit is in code learning mode S t e p 5 Note The dealer key will be erased when programmed to the customer key C O N S U M E R K E Y C O D I N G ON OFF Momentary Switch Push On Off Toggle Switch Push On ...

Reviews: