background image

5-Pin Power

Harness*

7921P

Controller

Shock Sensor

(White 4-Pin Socket****) 

Programmable Key Receptacle

for Changing to

Customer Mode

or

Putting Unit to Sleep Mode

Supplied with 5901H1, 5901H2 or 5901H3 Harness Kits or

 

Custom Starter/Disable T-harness.

**  

Supplied with 5902 Ignition Controlled Locking Kit.

*** 

Supplied with ALA-RPS, ALA-RPS2 or ALA-RPS3 relay packs.

****  For a Single-Zone Shock Sensor use ALA930.
 

For a Dual-Zone Shock Sensor use ALA95 or ALA90.

*****  This wire su12V power, if not used cut this wire
 

off at connector to prevent shorting.

Pink Wire Parking Lights Relay Input

Red/White Wire Parking Lights Relay Output

Violet Wire Positive Door Trigger Input

White/Black Wire Channel #2 Output

Green Wire Negative Door Trigger Input

Blue Wire Negative Pin Trigger Input 

Brown Wire 

Positive (+) Output for 

an Optional Electronic Siren

Blue/White Wire (-) Signal Output to

Disarm Factory Alarm

Gray Wire Horn (-) Pulsed Output

Starter Disable 

Socket*

Driver's Door

Lock

Unlock

Factory Keyless

Module

(Typical)

Left Door 

Lock/Unlock Switch

Lock

Unlock

Right Door 

Lock/Unlock Switch

Left Door

Jamb

Right Door 

Jamb

Lock (+)

Unlock (+)

Lock (+)

Unlock (+)

Right Front
Pass. Door

Left Rear
Pass. Door

Lock (+)

Unlock (+)

Right Rear
Pass. Door

Lock (+)

Unlock (+)

B

C

A

C

A

C

A

= Possible Connection Points for Green Wire

B

= Connection Point for Blue Wire

= Possible Connection Points for White Wire

Inside Door

Inside Door

Inside Vehicle

Green Wire

White Wire

Blue Wire

B

lack Wire

 (Unlock)

Re

d

 Wire

 (Lock)

O

ran

ge Wire

  ***** 

2nd Unlock Outp

ut (re

q

uires

additiona

l relay 

&

 special wiring).

Optional

5902 Harness

Auxiliary Interrupt

(Orange 2-Pin Socket***) 

Programmable Key

(Green 2-Pin Socket) 

Ignition Locking**

(Black 3-Pin Socket) 

LED

(White 2-Pin

Socket) 

Valet Switch

(Blue 2-Pin Socket) 

Arm/Disarm Harness

(White 3-Pin Socket) 

DIP Switches

Proposed

© 2005 Copyright Magnadyne Corp.

INSTALLATION INSTRUCTIONS

Model: 7921P

 

Summary of Contents for 7921P

Page 1: ...he factory installed power door locking system to arm and disarm the 7921P security system Step 3 5 Pin Power Harness Installation The power harness contains 3 wires and two vacant sockets this power harness does not come packaged with the alarm module but in 5901H1 5901H2 5901H3 harness kits or custom starter disable power interface harnesses Packaged with the 10 pin main harness are two loose wi...

Page 2: ...ronic Siren Blue White Wire Signal Output to Disarm Factory Alarm Gray Wire Horn Pulsed Output Starter Disable Socket Driver s Door Lock Unlock Factory Keyless Module Typical Left Door Lock Unlock Switch Lock Unlock Right Door Lock Unlock Switch Left Door Jamb Right Door Jamb Lock Unlock Lock Unlock Right Front Pass Door Left Rear Pass Door Lock Unlock Right Rear Pass Door Lock Unlock B C A C A C ...

Page 3: ...Arming of Alarm On Automatic Arming of Starter Disable On Both will arm 45 seconds after last door is closed 2 Beeps Automatic Arming of Alarm Off Automatic Arming of Starter Disable On The starter will disable 70 seconds after last door is closed 3 Red Remote Panic from Factory Keyless 1 Beep Panic On Entry Transmitter 2 Beeps Panic Off 4 Black Blue Safety Illumination Sentinel System 3 Beeps Saf...

Page 4: ...own for more than 3 seconds to get a second confirmation chirp For example 1 chirp 10 sec auto arm on auto door lock off 1 chirp 1 chirp 10 sec auto arm on auto door lock on REMOTE FEATURE PROGRAMMING USING THE CONSUMER S TRANSMITTER Consumer Remote Feature Programming 7921P 7920P 7919P Rev C FEATURE PROGRAMMING USING THE CONTROL MODULE S DIP SWITCHES The Silencer model 7921P control module offers...

Page 5: ... Auto Arm is ON Pre Programmed Consumer Mode Auto Arm 2 Beeps Automatic Arm Door Locking OFF Consumer Auto Arm is ON 3 Beeps Automatic Arm Door Locking On Consumer Auto Arm is OFF 4 Beeps Automatic Arm Door Locking OFF Consumer Auto Arm is OFF 3 Red Chirp Status Indicator On Off 1 Beep On 2 Beeps Off 4 Black Blue Selects P or S Mode Operation 4 Beeps Mode P See 2A Consumer Programming Automatic Ar...

Page 6: ...tton Consumer Switch Black Button Push the Valet Switch 3 Times for Red Button 6 Times for Black Button Represents 3 Times On Off A Long horn chirp indicates the unit is in code learning mode B LED comes on indicating the unit is in code learning mode W A K I N G U P A U N I T F R O M T H E S L E E P M O D E ON OFF Momentary Switch Push On Off Toggle Switch Push On then push it again for off S t e...

Page 7: ...e White Sleep Key into the Receptacle In the event the customer declines to purchase the Silencer security system and the system is not going to be removed from the vehicle it must be put into Sleep mode to prevent automatic arming The white sleep key can also be used to delete a dealer code and to reset the security system to it s original state as it was received from the factory Note The system...

Page 8: ...t Switch S t e p 2 Dealer Switch Red Button Consumer Switch Black Button Insert the Orange Delete Code Key into the Receptacle Upon the customer purchasing the 6905P or 6909P it will arm disarm from the factory keyless remotes He she also has the option of purchasing a customer key pack 5900PKP to disarm the security system In the event the customer declines to purchase the customer Key Pack 5900P...

Page 9: ...itch S t e p 1 Dealer Switch Red Button Consumer Switch Black Button Push the Valet Switch 3 Times for Red Button 6 Times for Black Button Represents 3 Times On Off A Long horn chirp indicates the unit is in code learning mode S t e p 5 Note The dealer key will be erased when programmed to the customer key C O N S U M E R K E Y C O D I N G ON OFF Momentary Switch Push On Off Toggle Switch Push On ...

Reviews: