IM-FULL-30SL rev A
5
Gray wire – (-) 200mA Channel 3 (Trunk) Output –
This will become a 1 second pulse ground by activating (button 3)
on the transmitter for two seconds. The current
capacity of this wire is 200 mA. This feature allows you to remote control trunk release or other electronic device.
(A relay may be required).
Orange wire – (-) 200mA Grounded Output When Armed –
This wire will become grounded when the alarm is armed. The current capacity of this wire is 200mA. This output can
control starter disable, when an intrusion is detected and the system is triggered. This prevents any unauthorized starting
of the vehicle.
87
87a
85
30
86
IN4003 Diode
Orange wire
from control module
“Start”
“On”
Purple wire
X
Cut
Yellow
wire
White wire
“Acc”
“Off”
Starter
VIOLET wire (Starter output)
form Heavy Gauge wire harness
Red wire to
Ignition Switch
Yellow wire - 12 volt with the ignition ON +
Connect this wire to a 12 Volt source when the ignition of the vehicle is in the
ON
position.
Green wire – Negative Door Switch Sensing Input (Zone 3) –
This wire is the ground trigger input wire for the negative door pin switch. This wire is the connection
for “grounding” type factory door pins. Locate the “common wire” that connects the door pin switches.
Make the connection of the GREEN Wire here.
Blue wire – Ground Instant Trigger Input (Zone 2) –
This wire is the ground trigger input wire for hood and or trunk pin switches.
Violet wire – Positive Door Switch Sensing Input (Zone 3)–
This wire is the positive trigger input wire for the positive door pin switch. This wire is the connection
for “positive” type factory door pins (typical FORD MOTOR). Locate the “common wire” for all door pins
and make the connection of the VIOLET Wire here.
Brown / White wire wire – (-) 200mA Programmable Output Horn Output –
This wire is provided to use the existing vehicle’s horn
as the alarm system’s optional warning audible device.
It’s a transistorized low current output, and should only
be connected to the low current ground output from the
vehicle’s horn switch. When the system is triggered, the
horn will sound.
Factory Security Rearm Signal Output –(See Alarm Feature Programming) –
This output is programmable. If programmed to rearm a factory installed security system, this wire will supply a pulse
whenever the remote start times out or is shut down using the transmitter and remote door locking.
85
86
87
87a
30
Brown/White
wire
To horn
+ 12 V
+12V Or Ground
Depending On System
Requirements
FUSE