3-1
CHAPTER 3
INTERFACE
This chapter describes 4 types of the interface specifications which are required to connect the host device
with the printer.
Irrespective of the interface used, amount of the input buffer in the printer is 4k bytes, and transmission
buffer is 768 bytes. If the transmission buffer becomes the condition of the buffer full, the printer waits data
processing until the buffer can be received data. Be aware that printing process does not performed in that
meantime.
3.1 SERIAL INTERFACE SPECIFICATIONS (RS-232C CONFORMITY)
(1) General
specifications
Item Specification
Synchronization
Asynchronous
Signal level
MARK = –3.0 to –15.0 V: Logic '1'
SPACE= +3.0 to +15.0 V: Logic '0'
Baud rate
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data bit length
*1
7 bits or 8 bits
Stop bit length
1 bit or 2 bits
Parity
None, odd or even
Reset
Break signal input to RxD (20ms or longer)
*1: When selecting 7 bits, the data transmission such as the status from a printer is not performed.
Also, the command that uses 80H and more parameters and character printing over 80H
are not available.
(2) Pin
assignment
Pin No.
Name
I/O
Function
1 N.C. -
No
connection
2
TxD
O
Sends data from the printer to the host device.
3 RxD I
Receives data from the host device.
Break signal input (SPACE) resets the printer.
4
-
-
Internally connected with pin No.6.
5 GND -
Signal
ground
6
-
-
Internally connected with pin No.4.
7
CTS
I
Outputs SPACE when the host device can receive data.
8
RTS
O
Outputs SPACE when the printer can receive data.
Summary of Contents for DPU-S445 SERIES
Page 1: ...DPU S445 SERIES THERMAL PRINTER TECHNICAL REFERENCE U00110811309 ...
Page 90: ...6 43 Figure 6 10 Print Sample 5 ...
Page 100: ...6 53 Figure 6 12 Print Sample 6 ...
Page 126: ...6 79 Figure 6 24 Print Sample 12 ...
Page 128: ...6 81 Figure 6 26 Print Sample 13 ...
Page 130: ...6 83 Figure 6 28 Print Sample 14 ...