6-104
GS 'g' '2' m nl nh
Maintenance Counter Transmission
Code
1DH 67H 32H m nl nh
m=0
(nh
×
256+nl)=20, 21, 70, 148, 149,198
Function Transmits the maintenance counter value.
Transmits the maintenance counter value. The initial value of the maintenance counter
becomes the value saved in the system area. Specifies the maintenance number as (nh
×
256+nl).
nh
×
256+nl
Hexadecimal Decimal
Counter type
14
20
Line number of paper feed (in 100-dot line)
15
21
Number of head activation times (in 100-dot line)
46
70
Drive time of printer unit (in minutes)
94
148
Line number of paper feed (every 100-dot line)
1
*
95
149
Number of head activation times (every 100-dot line)
1
*
C6
198
Drive time of printer unit (in minutes)
1
*
*1:The value is accumulated without being reset.
Configuration of the maintenance counter data
Hexadecimal
Decimal
Number of data
Data
30H to 39H
48 to 57
10 bytes