MA MCTS II, Ver. 1.4
12
11/2018
SIGNALTEC GmbH, Reutersbrunnenstrasse 27, D-90429 Nürnberg, GERMANY, T. +49 911 2550993-0, F. +49 911 2550993-13, Email: [email protected], Web: www.signaltec.com
7.4.2. Active plug-on voltage amplifier specifications
The output voltage level the transducer can drive is
limited. The active plug-on burden modules combine a
very precise burden resistor with a highly accurate
voltage amplifier. The plug-on burden voltage modules
deliver 7 V
rms
(9.9 V
pk
) at transducer nominal value.
The active plug-on voltage output modules are powered by the 3-pole D-SUB on the back
panel of the system.
Order
Number
Input
Resistance
Accuracy
[% of V + % of R]
Max. Output
Voltage
Bandwidth
Phase
Error
Load
Influence
MCTS/VM1/0.02
1 Ω
0.01 % + 0.01 %
7 V
rms
@ 1000 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
MCTS/VM0.66/0.02
1.5
Ω
0.01 % + 0.01 %
7 V
rms
@ 667 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
MCTS/VM0.4/0.02
2.5 Ω
0.01 % + 0.01 %
7 V
rms
@ 400 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
MCTS/VM0.26/0.02
3.75 Ω
0.01 % + 0.01 %
7 V
rms
@ 267 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
MCTS/VM0.2/0.02
5 Ω
0.01 % + 0.01 %
7 V
rms
@ 200 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
MCTS/VM0.1/0.02
10 Ω
0.01 % + 0.01 %
7 V
rms
@ 100 mA
rms
> 300 kHz
< 1⁰ @ 100 kHz
< 0.1 ppm/mW
Mechanical Data
Width:
Height:
Depth:
Mass:
51 mm
51 mm
62 mm (Connectors included)
105 g