Chapter 3: Settings
3-1.Memory Switch settings
The Memory Switches store the controller settings.
When changing Memory Switch settings use the Sample software (SGSample), which can be
downloaded from
http://www.global-optosigma.com/en_jp/software/sample_en.html
*) After changing Memory Switch, be sure to reboot the power HSC-103.
3-2. Memory Switch contents list and detailed settings
3-2-1 General
No
Memory Switch contents
Setting Range / Select items
Default Value
1
SPD SEL
1
~
4
1
2
SPD 1 S
1
~
999999999
10000
3
SPD 1 F
1
~
999999999
100000
4
SPD 1 R
1
~
1000
200
5
SPD 2 S
1
~
999999999
30000
6
SPD 2 F
1
~
999999999
300000
7
SPD 2 R
1
~
1000
200
8
SPD 3 S
1
~
999999999
70000
9
SPD 3 F
1
~
999999999
700000
10
SPD 3 R
1
~
1000
200
11
SPD 4 S
1
~
999999999
100000
12
SPD 4 F
1
~
999999999
1000000
13
SPD 4 R
1
~
1000
200
14
IO_LVL
ACT HIGH/ACT LOW
ACT HIGH
1) SPD SEL
:
Speed selection at Power ON
Select the initial setting Speed No. at Power ON.
[Setting Range]
1 ~ 4
2)
~
13) Speed 1
~
4(S)(F)(R)
:
Speed Setting
Set 4 kinds of travel stage Speed (minimum S, maximum F, and acceleration/deceleration time R) at
Power ON. When JS-300/301(Option) operation and during the internal program behavior, work in this
movement speed setting.
[Setting Range]
S
:
1
~
999999999 (Unit
:
0.01[
μ
m/s])
F
:
1
~
999999999 (Unit
:
0.01[
μ
m/s])
R
:
1
~
1000 (Unit
:
[ms])
*) Minimum S values should be set smaller than maximum F at Speed Setting.