SIGLENT 

22    SPD3000X QuickStart

 

2.10 Version information 

Short  press 

 

button  to  enter  Version  Information

 

interface,  which  is 

shown below:     

 

 

 

Long press 

 

button in any interface to open keylock function, which will 

make all the keys invalid, and the graphic logo of 

“lock” will display at the same 

time. 

 

Long press 

 

button again to close the keylock function and the graphic 

logo of 

“lock” will disappear at the same time. 

 

 

 

 

 

 

 

Summary of Contents for SPD3303X

Page 1: ...Quick Start SPD3303X 3303X E Programmable DC Power Supply QS0503X E01B 2015 SIGLENT TECHNOLOGIES CO LTD ...

Page 2: ......

Page 3: ...OGIES CO LTD Statement SIGLENT products are protected by patent laws in and outside of the P R China SIGLENT reserves the rights to change the specification and price Information in this publication replaces all previous corresponding published material Contents in this manual are not allowed to be copied extracted or translated in any form or by any means without SIGLENT s permission ...

Page 4: ...the fuse burned out before replacing the fuse Ground the instrument The instrument is grounded through the protective terra conductor of the power cord To avoid electric shock the grounding conductor must be connected to the earth Make sure that the instrument is properly grounded before any inputs or outputs Observe all terminal ratings To avoid fire or electric shock please observe all ratings a...

Page 5: ...ere To avoid personal injury or damage to instrument please do not operate in an explosive atmosphere Keep surface of the product clean and dry To avoid dust or moisture in the air influence the performance of the instrument please keep surface of the product clean and dry ...

Page 6: ...ates direct injury or hazard that may happen WARNING Indicates potential injury or hazard that may happen CAUTION Indicates potential damage to the instrument or other property that may happen Symbols may appear on the product Hazardous Protective Warning Earth Power Voltage Earth Ground Ground Switch ...

Page 7: ...X 3303X E 4 3 TFT color LCD display with content of 16M Three independent outputs two of which are adjustable and the total power up to 195W Four kinds of input voltage values includes 100V 110V 220V and 230V to satisfy different requirements Function of storage and call setting parameters Function of timing output Function of waveform display Real time display of voltage or current waveforms with...

Page 8: ...2 Control panel operation 10 2 1 Output summary 11 2 2 CH1 CH2 Independent Output 12 2 3 CH3 Independent mode 13 2 4 CH1 CH2 Series mode 14 2 5 CH1 CH2 Parallel mode 15 2 6 LAN setting 16 2 7 Save and Recall 17 2 8 Timer 18 2 9 Waveform display 21 2 10 Version information 22 2 11 Upgrade firmware 23 Chapter 3 Remote control 26 3 1 Syntax Conventions 27 3 2 Command list 28 3 3 Command description 2...

Page 9: ...anel and display Interface of SPD3303X 3303X E as well as the new machine inspection and attentions at first use Reading this chapter will give you a quick understanding on operation Brief introduction General Inspection The front panel The rear panel User interface The rear panel Output check ...

Page 10: ...ssed both electrical and mechanical tests The consigner or carrier will be responsible for damages to the instrument resulting from shipment SIGLENT would not provide free maintenance or replacement 2 Inspect the instrument If there are instruments found damaged defective or failure in electrical and mechanical tests please contact SIGLENT 3 Check the accessories Please check the accessories accor...

Page 11: ... DIP Switch at the rear panel according to the actual demand Warning To switch to the wanted power voltage please disconnect the power cord first Electrical Check Please use the power cord provided as accessory and connects the instrument to AC power Check the power as the following steps 1 Connect the power supply Warning To avoid electric shock please make sure that the instrument is grounded co...

Page 12: ...ea 10 Power Switch 3 Model 11 CH1 Output Terminal 4 System parameter configuration button 12 Ground Terminal 5 Multi function knob 13 CH2 Output Terminal 6 Fine Adjust button 14 CV CC indicator light 7 Right Left Direction button 15 CH3 Output Terminal 8 Channel Control button 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 ...

Page 13: ...o enter the LAN setting and storage function interface Press the button to enter timer setting interface Press the button longer to turn on off the keylock function and shorter to turn to system information interface Buttons for controlling the channel Press the button to turn on off all the channels Press the button to select CH1 as the current channel Press the button to select CH2 as the curren...

Page 14: ...ton Press the button to move the cursor around The output terminal on front panel The output terminals of CH1 CH2 and CH3 include positive terminal and negative terminal and a common ground for CH1 and CH2 additional Each channel has its own logo The operation details are introduced in the follow up control panel operation ...

Page 15: ... Channel logo 3 Operating mode logo The corresponding logo will display when working in CV or CC mode 4 LAN logo It will display when there is a LAN connection 5 USB logo It will display when there is a USB connection 6 Set value 7 Readback value 8 Timer lD Timer state identification 9 Channel output on off logo 6 7 9 8 1 2 3 4 5 ...

Page 16: ...e DIP switch of the AC power and its identification 3 The description of the AC input voltage 4 AC power socket 5 The fan air vents 6 CE certification mark 7 USB interface and identification 8 LAN interface and identification 9 TÜ V certification mark 1 2 6 5 4 3 7 8 9 ...

Page 17: ...d make sure the setting current values of all channels are not zero 2 Turn on CH1 CH2 and the instrument work in constant voltage mode Check whether the voltage value could be changed from 0V to 32V 2 Current output check 1 Turn on the power and make sure the setting current values of all channels are not zero 2 Use an insulated wire to connect the positive and negative terminal of CH1 CH2 3 Turn ...

Page 18: ...ol panel will be introduced in detail to give you an all around understanding of it which will eventually lead to easier work Brief introduction Output summary CH1 CH2 independent output CH3 independent output Series output Parallel output LAN setting Save and recall Timer Waveform display Version information Upgrade firmware Keylock ...

Page 19: ...t of the single channel In the series mode the voltage value is twice that of the single channel Constant voltage current In the constant current mode independent or tracking mode the current value is rated and controlled through the front panel The indicator light displays red and the voltage value is under rating It will return to constant voltage mode when the current value is under dating In t...

Page 20: ...egative terminals of CH1 CH2 3 Set voltage and current value of CH1 CH2 a Press 1 2 button to select the wanted channel b Move the cursor through direction button to select the wanted parameter voltage current c Press Fine to select the digit position and then revolve the multi function knob to change the corresponding parameter 4 turn on the output Press on off button to turn on the output the co...

Page 21: ...5V 3 2A Operation steps 1 Connect the load to the positive and negative terminals of CH3 on the front panel 2 Select the wanted voltage value by moving CH3 DIP switch 3 Turn on the output Press on off button to turn on the output the corresponding indicator light gets lighted immediately When the current value is higher than 3 2A the overload indicator light turns red and the working mode turns to...

Page 22: ... displays at the top of screen 2 Connect the load to the positive terminal of CH2 and the negative terminal of CH1 3 Set voltage and current value a Press 1 button to select the channel 1 b Move the cursor through direction button to select the wanted parameter voltage current c Press Fine to select the digit position and then revolve the multi function knob to change the corresponding parameter 4...

Page 23: ... top of screen 2 Connect the load to the positive and negative terminal of CH1 3 Set voltage and current value a Press 1 button to select the channel 1 b Move the cursor through direction button to select the wanted parameter voltage current c Press Fine to select the digit position and then revolve the multi function knob to change the corresponding parameter 4 Press on off button corresponding C...

Page 24: ...ver in the current network will assign the network parameters such as the IP address for the instrument OFF you can set the IP address subnet mask and gateway manually Revolve the multi function knob to change the digit Press Fine to select the digit position Press the direction button to move the cursor around Press the multi function knob to store the setting The setting is effective only when t...

Page 25: ... 5 Press direction button to move the cursor to OPER CHOICE 6 Move the cursor to STORE by revolving the multi function knob and then press it to save the current setup Recall setup Operation steps 1 Short press IP Store button and then long press IP Store button to enter Store Recall interface 2 Press direction button to move the cursor to FILE CHOICE 3 Select the wanted file by revolving the mult...

Page 26: ...tive output and the longest time of each group is 10000s Setup timer Operation steps 1 Press TIMER to enter the Timer Setup interface and the indicator light turns bright immediately 2 Press 1 2 button to select the wanted channel 3 Move the cursor to select the wanted parameter voltage current time by pressing the direction button 4 Set the corresponding value through Fine button and multi functi...

Page 27: ...evolve the multi function knob to make the Timer state to ON 4 Press the knob to start the Timer 5 Revolve the multi function knob to make the Timer state to OFF Press the knob to turn off the Timer Method 2 1 Press Timer button to enter timer interface 2 Press 1 2 button to select the wanted channel 3 Press the multi function knob to start the Timer 4 Press the knob again to turn off the Timer ...

Page 28: ...ut when the timer is running then the countdown will stop And the countdown will continue when the channel output is turn on again The Timer will automatically turn off when the time reduces to 0 Note The timer function is invalid when the series mode or parallel mode is turn on ...

Page 29: ...meter 2 Press Wavedisp button to enter Waveform Display interface and the indicator light turns bright immediately 3 Press CH1 CH2 on off button to turn on the output the corresponding indicator light turns bright immediately and you can observe the real time changing of current voltage current Waveform interface Note Yellow line means voltage green line means current and axis of ordinate means vo...

Page 30: ...n interface which is shown below Long press button in any interface to open keylock function which will make all the keys invalid and the graphic logo of lock will display at the same time Long press button again to close the keylock function and the graphic logo of lock will disappear at the same time ...

Page 31: ...USB line or network cable having been connected perfectly and make sure the instrument is connected with the software normally 2 Click Version and then choose Upgrade in the drop down menu to enter the firmware upgrade dialogue See figure 1 Figure 1 3 Figure 2 shows the firmware upgrade dialog Choose Normal Mode and click file choosing icon a dialog will popup as it shows in figure 3 and then sele...

Page 32: ...4 As it shows in figure 4 click Upgrade a dialog will popup as it shows in figure 5 and then select the upgrade method USB USBTMC or LAN VXI11 The upgrade is finished when the progress bar complete and the instrument will run the version after upgrade ...

Page 33: ...pecific steps are below 1 Press the knob before powering on the instrument and the turn on the instrument and it will enter the guide procedure mode 2 After enter the guide procedure mode the upgrade method is almost the same as the first one But when the dialog popup as it shows in Figure 2 choose Fireware Mode Refer to method 1 on other operation step ...

Page 34: ... interface on the rear panel SCPI Standard Commands for Programmable Instruments is an ASCII based programming language which can be used to control power supply remotely by computer installed with EasyPower software or NI Measurement Automation In this chapter we mainly introduce and illustrate the SCPI SPD3303X 3303X E support ...

Page 35: ...d string A vertical bar separates parameter choices For example CH1 CH2 in the above command indicates that you can specify a channel The bar is not sent with the command string Angle brackets indicate that you must specify a value for the enclosed parameter For example the above syntax statement shows the voltage parameter in angle brackets You must specify a value for the parameter for example C...

Page 36: ...list 1 IDN 2 SAV 3 RCL 4 INSTrument Subsystem 5 MEASure Subsystem 6 CURRent Subsystem 7 VOLTage Subsystem 8 OUTPut Subsystem 9 TIMEr Subsystem 10 SYSTem Subsystem 11 IPaddr Subsystem 12 MASKaddr Subsystem 13 GATEaddr Subsystem 14 DHCP Subsystem ...

Page 37: ...n hardware version Typical Return Siglent Technologies SPD3303X SPD00001130025 1 01 01 01 02 V3 0 2 SAV Command format SAV 1 2 3 4 5 Description Save current state in nonvolatile memory Example SAV 1 3 RCL Command format RCL 1 2 3 4 5 Description Recall state that had been saved from nonvolatile memory Example RCL 1 4 INSTrument Command format INSTrument CH1 CH2 Description Select the channel that...

Page 38: ...nel query the current channel Example MEASure CURRent CH1 Typical Return 3 000 Command format MEASure VOLTage CH1 CH2 Description Query voltage value for specified channel if there is no specified channel query the current channel Example MEASure VOLTage CH1 Typical Return 30 000 Command format MEASure POWEr CH1 CH2 Description Query power value for specified channel if there is no specified chann...

Page 39: ...CH1 CH2 CURRent Description Query the current value of the selected channel Example CH1 CURRent Typical Return 0 500 7 VOLTage Command format CH1 CH2 VOLTage voltage Description Set voltage value of the selected channel Example CH1 VOLTage 25 Command format CH1 CH2 VOLTage Description Query the voltage value of the selected channel Example CH1 VOLTage Typical Return 25 000 ...

Page 40: ...OUTPut TRACK 0 Command format OUTPut WAVE CH1 CH2 ON OFF Description Turn on off the Waveform Display function of specified channel Example OUTPut WAVE CH1 ON 9 TIMEr Command format TIMEr SET CH1 CH2 1 2 3 4 5 voltage current time Description Set timing parameters of specified channel including group 1 2 3 4 5 voltage current time Example TIMEr SET CH1 2 3 0 5 2 Command format TIMEr SET CH1 CH2 1 ...

Page 41: ...e and the information of the equipment Typical Return 0 No Error Command format SYSTem VERSion Description Query the software version of the equipment Typical Return 1 01 01 01 02 Command format SYSTem STATus Description Query the current working state of the equipment Typical Return 0x0224 Note The return info is hexadecimal format but the actual state is binary so you must change the return info...

Page 42: ...tal display 1 CH2 waveform diplay 11 IPaddr Command format IPaddr IP address Description Assign a static Internet Protocol IP address for the instrument Example IPaddr 10 11 13 214 Note The command is invalid when the state of DHCP is on Command format IPaddr Description Query the current IP address of the instrument Typical Return 10 11 13 214 12 MASKaddr Command format MASKaddr NetMasK Descripti...

Page 43: ... 11 13 1 Note The command is invalid when the state of DHCP is on Command format GATEaddr Description Query the current gateway of the instrument Typical Return 10 11 13 1 14 DHCP Command format DHCP ON OFF Description Assign the network parameters such as the IP address for the instrument automatically Example DHCP ON Command format DHCP Description Query whether the automatic network parameters ...

Page 44: ... load is higher than the limited current value the working mode turns to CC from CV Question 4 How to deal with the upgrade failed Answer 4 Upgrade via guide procedure can be used if the upgrade failed see detail in 2 11 Upgrade firmware Question 5 Why the practical value is not the same with the set value over performance standard and even changes slowly on startup Answer 5 It s normal On startup...

Page 45: ...t To arrange for service or obtain a copy of the complete warranty statement please contact your nearest SIGLENT sales and service office Except as provided in this summary or the applicable warranty Statement SIGLENT makes no warranty of any kind express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no Event shall SIGLENT...