SIGLENT
44
SDS/SD User Manual
■
Alternative trigger
The trigger signal comes from two vertical channels when you use alternative
trigger. In this mode, you can observe two irrelative signals at the same time. You
can select different trigger types for two vertical signals, and selected types cover
edge, pulse, video and slope trigger. Trigger information of two channel signals
display on the bottom right of the screen.
Picture 2.8-8
Table 2-21 Set trigger mode to edge trigger function menu 1:
Option Setting
Instruction
Type
Alternative
When use alternative trigger, the trigger signal
comes from two vertical channels. In the mode,
you can observe two irrelative signals at a time.
Chann
els
CH1-CH2
Set the trigger channels
Source
CH1
CH2
Set trigger type information for CH1 signal
Set trigger type information for CH2 signal
Mode
Edge
Set trigger type of vertical channel signal to edge
Slope
Triggering on rising edge.
Triggering on falling edge.
Triggering on rising edge and falling edge.
Set up
Enter “Trigger setup menu” (See table 2-14).