![Sifam Tinsley ND20LITE User Manual Download Page 7](http://html.mh-extra.com/html/sifam-tinsley/nd20lite/nd20lite_user-manual_1267046007.webp)
7
Fig. 1. Meter fitting
Fig. 2 Meter overall dimensions
4.
INSTALLATION
The ND20LITE meter is adapted to be fixed on a panel by means of
holders. The fitting way is presented on the fig.1.
Housing overall dimensions: 96 x 96 x 77 mm. At the rear side of the
meter, there are screw terminal strips which enable the connection of
external wires with a cross-section up to 2.5 mm
2
.
One must prepare a 92.5
+0.6
x 92.5
+0.6
mm cut-out in the panel.
The material thickness which the panel is made from should not exceed
15 mm. Insert the meter from the frontal panel side with the disconnec-
ted supply voltage. After the insertion into the hole, fix the meter by
means of holders.