Selection of the monitored value:
Table 6
Item/
value
in re-
gister
4015
Displayed parameter
Kind of quantity
Value for the percentage
conversion of alarm valu-
es and outputs (100%)
00
off
lack of quantity /alarm disabled/
none
01
U_1
voltage of phase L1
Un [V] *
02
I_1
current in the phase wire L1
In [A] *
03
P_1
active power of phase L1
Un x In x cos(0
°
) [W] *
04
q_1
reactive power of phase L1
Un x In x sin(90
°
) [var] *
05
S_1
apparent power of phase L1
Un x In [VA] *
06
PF1
active power factor PF of phase L1
1
07
tg1
tg
j
coefficient of phase L1
1
08
U_2
voltage of phase L2
Un [V] *
09
I_2
current in the phase wire L2
In [A] *
10
P_2
active power of phase L2
Un x In x cos(0
°
) [W] *
11
q_2
reactive power of phase L2
Un x In x sin(90
°
) [var] *
12
S_2
apparent power of phase L2
Un x In [VA] *
13
PF2
active power factor PF of phase L2
1
14
tg2
tg
j
coefficient of phase L2
1
15
U_3
voltage of phase L3
Un [V] *
16
I_3
current in the phase wire L3
In [A] *
17
P_3
active power of phase L3
Un x In x cos(0
°
) [W] *
18
q_3
reactive power of phase L3
Un x In x sin(90
°
) [var] *
19
S_3
apparent power of phase L3
Un x In [VA] *
20
PF3
active power factor PF of phase L3
1