Operation and Configuration Guide 3.14
100
4118618
Status
Green
Off
oMG is not on or is initializing
Rapid flashing (Four per second) Searching for network connection
Three rapid flashes, then off for
one second (repeating)
Software update is in progress.
(DO NOT REBOOT OR POWER
DOWN THE oMG)
On solid
Network connection is up and
normal
Slow flashing (One per second)
Error status: either no card or
network settings are incorrect
External
Red
Off
Normal operation
On for two seconds, then off
(repeating)
Initial power connection made
Two flashes per second
The unit is shutting down due to a
temperature or voltage problem
Slow flashing (One per second)
Temperature is out of range
Rapid flashing (Four per second) Voltage is out of range (e.g. power
has been applied, but ignition has
not been detected)
Solid (with Green flashing)
BIOS is being updated. (DO NOT
REBOOT OR POWER DOWN
THE oMG)
All Three Rapid flashing (Four per second) Failed reboot multiple times, call
Support.
Table 2-2: LED Blink Patterns (Continued)