Parameterizing Steps
05.2006
6SE7087-2JD60 Siemens
AG
9-10
Operating Instructions
SIMOVERT MASTERDRIVES
Function diagram modules (function diagrams) are shown after the flow
chart for parameter modules stored in the unit software. On the first few
pages are the :
♦
setpoint and command sources (sheets s0 to s81), on the following
pages are the
♦
analog outputs and the display parameters (sheet a0) and the
♦
open-loop and closed-loop control types (sheets r0 to r5).
It is therefore possible to put together the function diagrams to exactly
suit the selected combination of setpoint/command source and
open/closed-loop control type. This will give you an overview of the
functionality parameterized in the units and of the necessary
assignment of the terminals.
The function parameters and visualization parameters specified in the
function diagrams are automatically adopted in the user menu
(P060 = 0) and can be visualized or changed there.
The parameter numbers of the user menu are entered in P360.
Reference is made in the function diagrams to the respective function
diagram numbers (Sheet [xxx]) of the detail diagrams (in the
Compendium).
Function diagram
modules