Messages
and Diagnosis
Error
No.
Data and operating errors
- Meaning
Description
94
Adjustment weight too low
The adjustment weight is too low in DS 3. Increase
the adjustment weight interval. The measured
values between successive adjustment weights
must have an interval of at least 5% of the
measuring range.
96
Tare T- invalid
The subtractive tare weight has been exceeded.
This error is generated in the following cases:
The gross value lies above the defined
permitted tare range for the taring command.
An externally specified tare value is negative.
100
Weight outside zero definition
range
Zero definition cannot be executed since the current
zero point lies outside the zero definition range
defined in DS 3 or the current gross value lies above
the highest defined weighing range value.
171 Checksum
error
Checksum error in data record 26.
The data was falsified or the DS versions do not
match.
172
Error saving data record
An error occurred while saving the data record to
the Flash memory.
173
Data record transfer error
An error occurred while transferring the data record.
The data record was not transferred.
Table 7-1
List of data and operating errors
7.6 Message List of Operating Messages (Asynchronous Errors)
If an error generates an operating message, the red SF LED on the front of the
module is illuminated. The incoming and outgoing operating messages are
signaled in the diagnostic buffer.
Error
No.
Operating messages
- Meaning
Description
1
Reboot due to error in RAM read-write
testing
The error can mean that the module is
defective.
2
Reboot due to watchdog error
The module had to be reset because of a
critical error.
3
Reboot due to program error
The error can mean that the module is
defective. Contact the SIWAREX Hotline.
4 Reserved
Reserved
5
Parameter error
The parameters are not consistent (the
7-40 SIWAREX