Weighing
Functions
5.7.2
DS 30 – Operating Errors
The byte displays the current operating errors.
Bit No.
Name
Comment
0
1= Reboot due to RAM error
See message list Chapter
1
1= Restart because of a watchdog error or program fault
See message list Chapter
2
1= No 24 V module voltage (can only be read in SIMATIC-
CPU, not with SIWATOOL MS)
See message list Chapter
3
1= Number overflow in weight calculation
See message list Chapter
4
1= Parameter error
See message list Chapter
5
1= AD converter at limit of measuring range
See message list Chapter
6
1= Minimum voltage undershot on sensor line
See message list Chapter
7
1= AD converter fault
See message list Chapter
Table 5-8
Operating error (Bit information)
5.7.3
DS 30 – Gross Process Value
The current gross weight value.
5.7.4
DS 30 – Net Process Value
The current net weight value.
5.7.5
DS 30 – Tare Process Value
The current tare weight value.
5.7.6
DS 30 – G/N Weight
The current weight value, which is shown in the scale’s main display (external
remote display, type Siebert S102 or ASCII).
5.7.7
DS 30 – G/N Weight_x10
The current weight value with a higher resolution, which can be displayed
temporarily in the main display (external remote display type Siebert S102 or
ASCII) for a duration of 5 seconds.
5.7.8
DS 30 – Tare
The current tare weight, in the resolution specified in the numeral step (DS3).
5.7.9
DS 30 – Unfiltered Raw Digit Value from AD Converter
The current digit value from the AD converter without digital signal filtering.
SIWAREX MS 5-33