Messages and Diagnostics
SIWAREX FTA
7-147
Error
No.
Data and
command errors -
description
Solution
132
Reserved
133
Reserved
134
Reserved
135
Reserved
136-
165
Plausibility error
Weighing
parameter
136 Start not possible
because the set
value is not
permitted
The set value in DR 20 is invalid. It may not be 0 nor may it be
greater than the maximum permitted set value for a single fill in
DR 23. Correct the parameter.
137
Reserved
138 Start not possible
since the fine shut-
off point is not
plausible.
Start not possible since the default for the trailing weight or the
shut-off correction value is not plausible. The following must
apply: (Current trailing - shut-off correction value) <= Set value.
Check the default in DR 22.
139
Reserved
140
Reserved
141 Start not possible
because of possible
overfilling
Start not possible since the defined set value does not match the
current scale status.
The following must apply:
Current gross + set value (DR20) – current tr shut-off
correction value < maximum weighing range
142 Start blocked
Start not possible since a blockage is set in weighing step 0.
143 Start not possible
since the loading
quantity or the
residual quantity is
too small
The defined loading quantity is too low or start is not possible
because the residual quantity that is still to be loaded is too little.
The quantity to be loaded in DR 21 is less than the defined
minimum weight definition in DR 3. Correct the value.
The quantity to be loaded in DR 21 is lower than the current
trailing weight in DR 22. Correct the value.
The quantity to be loaded in DR 21 is lower than the minimum
weighing range value in DR 3. Correct the values.
A dosage in AWI totalizing loading operation cannot be started
since the residual quantity is less than the defined minimum
weight. E.G. If everything has been loaded already or the
loading procedure has been aborted. Give command “Delete
calibratable distribution memory” (113) to activate a new loading
procedure.
144
Reserved
145 Start not possible
since the set value
< min. WB1
Start not possible since the set value is less than the minimum
weight of weighing range 1 DR 3. Increase the set value.
146 Reserved
Reserved
147 Start not possible
since tolerance limit
(n) is implausible
The tolerance definitions are not plausible.
During the start or while transferring the DR 20 or 22 in the cycle,
a set value was set which is less than at least one of the
tolerance limits TU2, TU1, TO1, TO2. Check tolerance definitions
or the set value.
148 Check stop not
possible
Check stop not possible since no check stop has been defined.