Dimension drawings
12.3 Flanged horn antenna
SITRANS LR250 (PROFIBUS PA)
Operating Instructions, 08/2014, A5E32221386-AC
193
Flanged Horn dimensions
Nominal horn
size
in mm (inch)
Horn O.D.
in mm (inch)
Height to sensor reference point, in mm
(inch)
a)
Beam angle
(°)
b)
Measurement range,
in m (ft)
Stainless steel flange:
raised or flat-face
Optional alloy
flange
c)
50 (2)
47.8 (1.88)
135.3 (5.32)
138.3 (5.44)
15
20 (65.6)
80 (3)
74.8 (2.94)
168.3 (6.62)
171.3 (6. 74)
10
100 (4)
94.8 (3.73)
223.3 (8.79)
226.3 (8.90)
8
a)
Height from bottom of horn to sensor reference point as shown: see Flanged horn antenna with
extension (Page 194). See also Raised-Face flange per EN 1092-1 for flanged horn antenna
(Page 219), or Flat-Face flange (Page 224).
b)
-3dB in the direction of the polarization axis (see Polarization reference point (Page 31) for an
illustration).
c)
Optional alloy N06022/2.4602 (Hastelloy
®
C-22 or equivalent). See Raised-Face Flange
Dimensions (Page 219).
Note
Heights to sensor reference point are for stainless steel flanges. For optional alloy
N06022/2.4602 (Hastelloy
©
C-22 or equivalent) see Flanged Horn dimensions above.