Procedure
As soon as the device has an internet connection, time will be set by NTP. See
chapter Administrating the network for SITRANS CC220 (Page 38).
1. Open the cover on the right.
2. Pull the plug of the battery cable
from the motherboard.
3. Remove the battery from the bat‐
tery box.
Insert the replacement battery, plug
in the battery cable on the mother‐
board and close the cover on the
right.
9.1.4
Replacing SITRANS CC220
Replacing a defective SITRANS CC220
1. Stop anomaly detection models of the SITRANS MS200 assigned to the defective SITRANS
CC220.
2. Replace defective SITRANS CC220 with new SITRANS CC220.
3. Disconnect defective SITRANS CC220 in SITRANS SCM IQ.
4. Connect new SITRANS CC220.
5. Reconnect old SITRANS MS200 with SITRANS SCM IQ to the same MindSphere asset.
6. Reset SITRANS MS200.
Resetting SITRANS MS200 (Page 51)
9.2
Maintenance and repair work for SITRANS MS200
9.2.1
Basic safety notes
The device is maintenance-free. However, a periodic inspection according to pertinent directives
and regulations must be carried out.
Service and maintenance
9.2 Maintenance and repair work for SITRANS MS200