Technical specifications
13.3 Technical specifications for POM
SIPLUS HCS4200
Operating Instructions, 11/2015, A5E35066204A/RS-AA/002
133
Mechanical data:
Mounting position
vertical
Mounting type
Screw mounting to rack
Type of ventilation
Self ventilation or forced ventilation
Vibration resistance
•
during operation / acc. to IEC 60068-2-6
10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1g
•
during storage / acc. to IEC 60068-2-6
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1g
Shock resistance
•
acc. to IEC 60068-2-27
15g / 11 ms / 3 shocks / axis
•
acc. to IEC 60068-2-29
25 g / 6 ms / 1000 shocks / axis
Protection class IP
IP20
Depth
281 mm
Height
285 mm
Width
36 mm
Electromagnetic compatibility:
EMC emitted interference
Limit value in accordance with IEC 61000-6-4:2007 + A1:2011
Conducted interference / due to burst / acc. to
IEC 61000-4-4
2 kV power supply lines, 2 kV load lines
Conducted interference / due to surge / acc. to
IEC 61000-4-5
Supply and load cables: 1 kV balanced, 2 kV unbalanced
Conducted interference / due to high-frequency
radiation / acc. to IEC 61000-4-6
10 V (0.15 ... 80 MHz)
Field-bound parasitic coupling / acc. to IEC
61000-4-3
10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7
GHz)
Electrostatic discharge / acc. to IEC 61000-4-2
4 kV contact discharg
e /
8 kV air
discharg
e
4 kV contact discharge / 8 kV air
discharge
Overvoltage category
III
Ambient conditions:
Ambient temperature
•
during operation
0 ... 55 °C
•
during storage
-25 ... +70 °C
•
during transport
-25 ... +70 °C
Air pressure
•
during operation
860 ... 1 080 hPa
•
during storage
660 ... 1 080 hPa
Degree of pollution
2
Installation altitude / at height above sea level /
maximum
2 000 m
Relative humidity
•
at 25 °C / during operation / maximum
95 %
•
at 50 °C / during operation / maximum
50 %
•
at 50 °C / during operation / maximum / Note 95% at 25 °C, decreasing linearly to 50% at 50 °C